    COD and nitrogen removal from refinery wastewater by aerated biofilter, A/O, MBR and ozone

    A refinery wastewater treatment plant in Guangdong Province designed for 300 m³/h, treating water from crude oil desalting, crude oil tank drainage and alkylation that carries refractory organics, ammonia and heavy metals. The water first passes an inclined-plate sedimentation tank, a cavitation air flotation tank and a dissolved air flotation tank, which lie before the sampled section. The aim was to bring strong refinery wastewater within the national discharge standard for the petrochemical industry.

    Treatment line

    1. 01Internal circulation biological aerated filterAerated pretreatment reactor with a retention time of 14 hours.
    2. 02Hydrolysis acidification tankRetention time of 25 hours, meant to improve biodegradability.
    3. 03First anaerobic-aerobic activated sludge unitRetention time of 24 hours and sludge age of 45 days.
    4. 04Second anaerobic-aerobic activated sludge unitRetention time of 28.8 hours; glucose is added as an extra carbon source.
    5. 05Membrane bioreactorRetention time of 3 hours.
    6. 06Ozone and activated carbon unitBreaks down the remaining refractory organics before discharge.

    What the source found

    Across the sampled section COD fell by 98%, total nitrogen by 84% and total phosphorus by 96%, and the final COD met the national discharge standard for the petrochemical industry. The aerated biofilter did most of the organic removal, while the hydrolysis tank did not improve biodegradability, probably because oxygen carried over from the biofilter, and denitrification in the second anaerobic-aerobic unit was weak. Sulfide was fully oxidized after the two anaerobic-aerobic units.

    Samples taken at seven points, from the outlet of the flotation stage to the outlet of the ozone and activated carbon unit, and analysed for organic load, nitrogen, phosphorus, sulfide and individual organic compounds.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    CODCODmg/L2,5545098%
    BOD5BOD5mg/L1,198not detected
    BOD5 to COD ratio0.469not detected
    Total organic carbonTOCmg/L6112097%
    C:N:P ratio257:28:1not detected
    Volatile fatty acidsVFAmg/L11.67not detected
    SulfideS2−mg/L8.24not detected
    Total nitrogenTNmg/L139.622.484%
    Ammonium nitrogenNH4-Nmg/L81.2not detected
    Nitrate nitrogenNO3-Nmg/L8.46.127%
    Nitrite nitrogenNO2-Nmg/Lnot detectednot detected
    Total phosphorusTPmg/L4.70.296%
    Organic acidsmg/L6483.399.5%
    Estersmg/L158597%
    Alcoholsmg/L1304.597%
    Heterocyclic compoundsmg/L1103.397%
    Alkanesmg/L5515.272%
    Aromatic hydrocarbonsmg/L122.877%
    Aldehydes and ketonesmg/L650.899%
    Phenolsmg/L97

    Inlet: flotation effluent entering the aerated biofilter. Outlet: outlet of the ozone and activated carbon unit. Mean values with standard deviations of samples taken at the two points; organic compound classes by semi-quantitative GC-MS. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.