    COD and oil removal from refinery wastewater by primary and secondary effluent treatment

    The wastewater treatment plant of an oil refinery in Palembang, which must bring its effluent within the national quality standard before discharge to a water body. It has a primary and a secondary effluent treatment stage, and the fall in BOD, COD and ammonia across them is put down to biological breakdown and nitrification.

    Treatment line

    1. 01Primary effluent treatment
    2. 02Secondary effluent treatment

    What the source found

    The plant removed about 57% of oil and grease, 38% of COD and 28% of BOD, and these falls were statistically significant, while the change in sulfide was small and not statistically significant and acidity stayed stable. The effluent met the national quality standard, but removal of BOD, COD and sulfide was judged below its potential, and better control of retention time and aeration or an added treatment unit was recommended.

    Twelve months of plant operating data at the inlet and outlet, January to December 2024, compared with paired statistical tests.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    AmmoniaNH3mg/L0.3910.1659%
    BODBODmg/L39.49228.328%
    SulfideS2−mg/L0.0350.027
    pH7.1817.239
    CODCODmg/L133.15883.21738%
    Oil and greaseO&Gmg/L14.0146.05357%

    Inlet: wastewater at the treatment inlet. Outlet: treated water at the treatment outlet. Means of 12 monthly values from January to December 2024. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.