COD and colour removal from recycled board wastewater by catalytic ozonation and biofilm
Pulping wastewater from a mill making paper from old corrugated containers in Dongguan, Guangdong, carries sticky dissolved and colloidal substances from glues, inks and resins that stand in the way of closing the mill's water loop. Samples of this real wastewater were treated in a laboratory reactor.
Treatment line
- 01Catalytic ozonationAn 8 minute ozone reaction over polyurethane sponge cubes coated with nano titanium dioxide, to break down hard-to-degrade organics before biological treatment.
- 02Aerated sponge biofilm reactorPolyurethane sponge cubes carrying a mix of acclimated activated sludge and white rot fungi, filling 9% of the reactor, aerated for 10 hours at neutral pH.
What the source found
The combined process removed 82% of COD, 86% of BOD, 78% of suspended solids and 94% of colour, and cut the sticky dissolved and colloidal solids sharply. Biological treatment alone removed far less COD and most of its microbes died, while after ozonation the biofilm stayed active, so the two steps worked together.
Laboratory runs comparing three microbial mixes, a response surface optimisation of pH, aeration, carrier filling and time, and analysis of the raw wastewater, the ozonated water and the final effluent.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| COD | COD | mg/L | 953 | 176 | 82% |
| BOD5 | BOD5 | mg/L | 254 | 36 | 86% |
| Ammonium as the ion | NH4+ | mg/L | 24.23 | 7.3 | |
| Total nitrogen | TN | mg/L | 13.55 | 9.2 | |
| Total phosphorus | TP | mg/L | 0.61 | 0.67 | 0% |
| Suspended solids | TSS | mg/L | 2,439 | 534 | 78% |
| pH | 7.8 | 7.2 | |||
| Colour (chromaticity) | 1,789 | 114 | 94% | ||
| Zeta potential | mV | -24.31 | -16.64 | ||
| Dissolved and colloidal substances solid content | g/L | 1.63 | 0.46 | 72% | |
| Average particle size | nm | 523.4 | 218 |
Inlet: raw recycled board mill wastewater. Outlet: effluent after catalytic ozonation and the sponge biofilm reactor. Laboratory runs at the optimised conditions; one value per point. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.