Aguato

    Water reuse from sulfate-rich gas plant tail-gas wastewater by disc tube reverse osmosis

    A natural gas purification plant in Chongqing that cleans sulfur dioxide from its tail gas by oxidation and amine absorption, producing acidic scrubber water and salty rinse water from the amine cleaning unit. The combined wastewater is acidic, light yellow and rich in sulfate, and the line was built to recover it as reuse water meeting the national standard for miscellaneous water use. The reverse osmosis concentrate is neutralized again with sodium hydroxide and sent to a low-temperature vacuum evaporator at 37 °C, which yields a second reuse stream of condensate and a salt by-product.

    Treatment line

    1. 01Neutralization tankSodium hydroxide is added under stirring to bring the acidic wastewater close to neutral.
    2. 02Quartz sand filterPlaced ahead of the reverse osmosis module.
    3. 03Activated carbon filterPlaced ahead of the reverse osmosis module.
    4. 04Disc tube reverse osmosisPlate-and-frame module of 9.4 m² rated at 1.3 m³/h, fed at 1.0 m³/h and 3.5 MPa at 30 °C; the permeate is the main reuse water.

    What the source found

    From raw wastewater to reverse osmosis permeate, COD fell by 97%, BOD by 98%, total organic carbon by 99%, total nitrogen by 97%, suspended solids by 71% and sulfate by 99%, and ammonia was not detected in the permeate. Both the permeate and the evaporator condensate met the national standard for miscellaneous reuse, and almost all of the water was recovered, most of it as permeate, with the rest as condensate.

    Samples of the raw wastewater, the neutralized feed, the reverse osmosis permeate and concentrate, and the evaporator condensate, analysed for organic load, nitrogen, solids, ions and metals; figures shown run from the raw wastewater to the permeate.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH3.8
    CODCODmg/L207697%
    BOD5BOD5mg/L71.91.498%
    Total organic carbonTOCmg/L67.60.999%
    Ammonia nitrogenNH3-Nmg/L1.28not detected
    Total nitrogenTNmg/L70.52.0797%
    Suspended solidsTSSmg/L20.9671%
    Electrical conductivityECµS/cm142
    SulfateSO42−mg/L6,4799099%
    NitrateNO3−mg/L2.181.4733%
    ChlorideCl−mg/L11.60.6694%
    FluorideF−mg/L0.08not detected
    SulfiteSO32−mg/L459
    CalciumCamg/L0.0450.00491%
    MagnesiumMgmg/L0.0610.00592%
    BariumBamg/L0.013
    StrontiumSrmg/L0.022
    SodiumNamg/L28.648.10%
    PotassiumKmg/L30.10.3999%
    IronFemg/L0.59
    CopperCumg/L0.024
    ManganeseMnmg/L0.009

    Inlet: raw wastewater before neutralization. Outlet: permeate of the disc tube reverse osmosis. Single analyses of each stream; no sampling period or replicate count given. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.