Aguato

    Oil removal from produced water in an iron-dosed anaerobic, anoxic and aerobic biofilm reactor

    Produced water from chemical flooding at an oilfield, taken from the inlet of an oilfield treatment facility; it carries emulsified oil, suspended solids and residual polymer, and the treated water is meant for reinjection. It was treated in an experimental composite bioreactor with a total working volume of 240 litres, with ferric chloride added to strengthen the biological breakdown.

    Treatment line

    1. 01Nutrient and ferric iron dosingFerric chloride, urea and potassium phosphate were added to the incoming water.
    2. 02Two anaerobic zones48 litres each with suspended biofilm carriers; the main zone for oil, polymer and COD removal.
    3. 03Anoxic zone48 litres with biofilm carriers; receives water recycled from the aerobic zones.
    4. 04Two aerobic zones48 litres each with packing above the aerators to grow biofilm.
    5. 05Settling zone

    What the source found

    The reactor removed 99% of the oil and kept treated water oil within the reinjection standard, with the anaerobic zones doing most of the work. Suspended solids fell by 66% and ammonia by 92%, although ammonia rose in the anaerobic zones, which suggests that nitrogen bound in the polymer was being released. Long-chain hydrocarbons such as eicosane were largely broken down.

    Continuous operation at a 16-hour hydraulic retention time, with inlet, zone and outlet samples analysed over the run and organic compounds checked after 45 days.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    CODCODmg/L492.69
    Oil contentmg/L129.63below 199.2%
    Suspended solidsTSSmg/L144.6266%
    Polymermg/L42.51
    Ammonium nitrogenNH4-Nmg/L15.1792%
    ViscositymPa∙s0.7
    pH7.56
    UV absorbance at 254 nmAU/cm1.94

    Inlet: produced water at the reactor inlet. Outlet: outlet of the settling zone. Means over continuous operation at a 16 hour retention time; only the influent is printed as values, removals as stated percentages. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.