Aguato

    Oil and BTEX reduction in natural gas produced water by electrocoagulation

    Real produced water from the natural gas industry in Qatar was treated in 5 litre bench batches to see whether electrocoagulation could prepare it for reuse. The water carries a high organic load, oil, dissolved aromatic hydrocarbons and high levels of chloride and sodium.

    Treatment line

    1. 01DegassingThe water was aerated for about two hours and the stripped gases were bubbled into sodium hydroxide solution.
    2. 02ElectrocoagulationIron and aluminium plate electrodes 1 cm apart, powered from a photovoltaic cell, run for 30 minutes at constant voltage.
    3. 03SettlingClear water was pumped from the middle of the beaker after the flocs settled.

    What the source found

    Electrocoagulation removed most of the oil and more than 99% of the BTEX compounds, and cut COD by 33%. Heavy metals and salts were judged to change little and iron rose in the treated water, so further treatment, such as membranes, is advised before reuse. Turbidity and suspended solids fell only partly during electrocoagulation, and a centrifuge step afterwards removed most of what remained.

    Samples every 5 minutes over a 30 minute electrocoagulation run, compared with a full laboratory analysis of the untreated water.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    CODCODmg/L3,7902,52533%
    Total organic carbonTOCmg/L1,320.361953%
    BromideBr−mg/L59.760.30%
    ChlorideCl−mg/L9,3607,835.62
    Oil and greaseO&Gmg/L44.8<10
    FluorideF−mg/L0.59
    Nitrite nitrogenNO2-Nmg/L<0.01
    PhosphatePO43−mg/L2.6
    SulfateSO42−mg/L76.9770%
    BromateBrO3−µg/L<5<5
    ChloriteClO2−mg/L0.57
    ChlorateClO3−mg/L69.86
    NitrateNO3−mg/L0.38
    CadmiumCdmg/L<0.005<0.005
    ChromiumCrmg/L0.0960.02970%
    PotassiumKmg/L208.322231.1550%
    SodiumNamg/L2,768.92,664.13.8%
    SilicaSiO2mg/L4.9223.23434%
    CopperCumg/L0.067
    IronFemg/L6.79192.177
    LeadPbmg/L0.089
    MercuryHgµg/L<0.01
    BoronBmg/L10.69.9616.0%
    ManganeseMnmg/L0.279
    BariumBamg/L0.2230.12444%
    ZincZnmg/L0.1480.03477%
    ArsenicAsµg/L<0.200
    SeleniumSeµg/L<0.200
    SulfurSmg/L176.75.78697%
    StrontiumSrmg/L29.85228.783.6%
    AluminiumAlmg/L0.698
    LithiumLimg/L4.0743.8555.4%
    MolybdenumMomg/L0.036
    Tolueneµg/L36,33043299%
    Ethylbenzeneµg/L1,3221199.2%
    Xylenesµg/L13,43012999.0%
    Benzeneµg/L72,2721,02499%

    Inlet: untreated produced water. Outlet: water after 30 minutes of electrocoagulation and settling. One bench batch run, sampled before treatment and after 30 minutes of electrocoagulation. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.