Manganese and iron removal from oilfield produced water by sequential batch activated sludge
Real produced water from an oilfield, which carries salts, organic matter and metals and must be treated before discharge. It was treated in a small laboratory reactor with activated sludge taken from a local sewage plant, as a pretreatment ahead of a 13 litre microalgae photobioreactor.
Treatment line
- 01Sequential batch reactor with activated sludgeA 3.3 litre reactor run in fill, react, settle and draw cycles, with the cycle shortened from 24 to 6 hours and a hydraulic retention time of 6 hours.
What the source found
The activated sludge stage lowered manganese by 77%, iron by 67% and dissolved solids by 33%. In the following microalgae stage organic carbon, barium, iron and manganese fell further, but salinity did not drop, and copper and molybdenum rose, probably because of the algae's culture medium.
The raw produced water and the water leaving the activated sludge reactor were each analysed for salinity, dissolved solids, organic carbon and metals. The photobioreactor was sampled separately.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 8.41 | 7.63 | |||
| Salinity | PSU | 7.86 | 5 | ||
| Total dissolved solids | TDS | ppm | 6,795 | 4,583 | 33% |
| Total organic carbon | TOC | ppm | 630 | 120 | 81% |
| Electrical conductivity | EC | mS/cm | 12.91 | 9.16 | |
| Arsenic | As | mg/L | < 0.010 | < 0.010 | |
| Barium | Ba | mg/L | 1.868 | 1.234 | 34% |
| Cadmium | Cd | mg/L | < 0.005 | < 0.005 | |
| Cobalt | Co | mg/L | 0.005 | 0.005 | 0% |
| Chromium | Cr | mg/L | 0.019 | 0.005 | 74% |
| Copper | Cu | mg/L | 0.262 | 0.063 | 76% |
| Iron | Fe | mg/L | 0.469 | 0.155 | 67% |
| Manganese | Mn | mg/L | 24 | 5.49 | 77% |
| Molybdenum | Mo | mg/L | 0.01 | 0.01 | 0% |
| Nickel | Ni | mg/L | 0.01 | 0.01 | 0% |
| Lead | Pb | mg/L | < 0.010 | < 0.010 |
Inlet: raw produced water. Outlet: treated water drawn from the activated sludge batch reactor. One characterisation of the raw produced water and of the pretreated water after the activated sludge reactor. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.