Nutrient removal from sewage of 15,000 people by activated sludge and chemical precipitation
A municipal treatment plant in the metropolitan area of Vienna serving about 15,000 connected inhabitants, designed for 45,000 population equivalents with an average loading of about 20,000. The catchment mixes rural and urban areas on a combined sewer, and wine production in the catchment may affect the raw wastewater in season. Phosphorus removal is required for sensitive areas under EU rules.
Treatment line
- 01Mechanical treatmentPrimary mechanical step ahead of the biological stage.
- 02Activated sludge with nitrification and denitrificationRemoves organic carbon and nitrogen.
- 03Chemical phosphorus precipitationPhosphorus is precipitated with iron or aluminium salts, or both.
What the source found
Over the year the plant removed 96% of COD, 78% of total nitrogen and 92% of phosphorus. Across the five conventional plants studied, whose results were pooled, genetic markers of human faecal pollution were still found in high concentrations in the treated effluent.
Daily plant data from 24-hour flow-proportional samples, cross-checked by the researchers' own 24-hour composite samples of raw and treated wastewater taken every 4 to 6 weeks over one year; the figures are medians.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| COD | COD | mg/L | 555 | 24 | 96% |
| Total phosphorus | TP | mg/L | 8.5 | 0.7 | 92% |
| Total nitrogen | TN | mg/L | 63 | 14 | 78% |
| Nitrate nitrogen | NO3-N | mg/L | 11 | ||
| Ammonium nitrogen | NH4-N | mg/L | 0.4 |
Inlet: raw wastewater at the plant inlet. Outlet: treated wastewater at the plant outlet. Medians over one year of 24-hour flow-proportional composite samples. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.