COD and BOD removal from rice vermicelli wastewater by Fenton oxidation and activated sludge
A rice vermicelli factory in Hau Giang Province, Vietnam, with one production line making 400 to 600 kg a day, discharges about 5 m³/day of acidic, starch-rich and salty wastewater from soaking, boiling and cleaning. Wastewater taken after the factory's settling stage was treated in a laboratory model, and the result was compared with the national discharge standard for industrial wastewater.
Treatment line
- 01Fenton reaction tankStirred 20 L batches dosed with ferrous sulphate and hydrogen peroxide under acidic conditions for 90 minutes, then neutralised with sodium hydroxide to form iron flocs.
- 02Settling tankIron hydroxide flocs settle out, taking suspended solids and part of the organic matter with them.
- 03Intermediate tankHolds the pretreated water before it is pumped to the biological stage.
- 04Activated sludge aeration tank15 litre batches with fine-bubble aeration and 14 hours of retention, seeded with sludge from a seafood processing plant; nitrogen and phosphorus are added as NPK fertiliser.
- 05Settling tankActivated sludge settles for 2 hours before the treated water is drawn off.
What the source found
The Fenton stage made the wastewater more biodegradable, and the combined line removed 96% of COD and 96% of BOD, meeting the national discharge standard, whereas Fenton alone left COD and BOD above it. The biological stage removed less than expected because of the high dissolved salt content, suspended solids rose slightly across it from biomass growth, and the Fenton stage produced a large volume of iron sludge that needs handling. The whole line took about 16 hours.
Raw wastewater characterised from morning samples on three consecutive days; each laboratory run was repeated three times and averages were reported at the inlet and outlet of the model.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 4.12 | ||||
| COD | COD | mg/L | 2,148.68 | 94.65 | 96% |
| BOD5 | BOD5 | mg/L | 1,159.8 | 46.14 | 96% |
| Suspended solids | TSS | mg/L | 430.01 | 73 | 83% |
| Total dissolved solids | TDS | mg/L | 4,475 | approximately 5000 | |
| Total nitrogen | TN | mg/L | 19.82 | 3.2 | 84% |
| Total phosphorus | TP | mg/L | 3.37 | 0.55 | 84% |
Inlet: raw rice vermicelli wastewater. Outlet: treated water after the activated sludge settling tank. Averages of three repeated laboratory runs; raw water from morning samples on three consecutive days. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.