BOD and COD removal from palm oil refinery effluent by coagulation with a tannin coagulant
A palm oil refinery in Selangor uses a chemical refining process to turn crude palm oil into refined oil. Its raw effluent is above the national industrial discharge limits for BOD, COD and suspended solids, so a plant-based tannin coagulant was tested in the laboratory as an alternative to metal-salt coagulants that leave hazardous sludge.
Treatment line
- 01Coagulation and flocculationJar tests on 500 mL of raw effluent with a cationic tannin coagulant: 3 min of fast mixing, then 60 min of slow mixing to build flocs.
- 02Sedimentation60 min of settling before the treated water was analysed.
What the source found
At the best conditions the tannin removed 98% of BOD, 89% of COD and 90% of suspended solids, and the raw effluent needed no acid or alkali to reach the best conditions. BOD and COD met the less strict of the two national discharge standards, but suspended solids stayed above it and further work was judged necessary.
Jar tests varied pH, coagulant dose, mixing time, settling time and temperature, and the best conditions were used for the reported residual values.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 5.86 | ||||
| Temperature | °C | 28 | |||
| BOD | BOD | mg/L | 518 | 12 | 98% |
| COD | COD | mg/L | 1,350 | 150 | 89% |
| Suspended solids | TSS | mg/L | 1,430 | 140 | 90% |
| Turbidity | mg/L | 464 | 32 | 93% |
Inlet: untreated refinery effluent. Outlet: supernatant after coagulation with tannin and 60 min settling. Laboratory jar tests at the best conditions found (pH 6, 200 mg/L tannin, 60 min coagulation, 60 min settling). Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.