Zero discharge of palm oil mill effluent by anaerobic EGSB, aerobic tank, MBR and membranes
An industrial pilot plant at a palm oil mill treated its effluent, a hot, acidic liquid very high in organic matter, oil and solids, aiming at zero discharge with recovery of oil, biogas, reusable water and fertiliser. Ahead of the section described here, a rotary screen with grit separator and an oil-water separator tank remove solids and recover oil; after it, ultrafiltration and reverse osmosis produce water for boiler feed, and the reverse osmosis concentrate and anaerobic sludge are meant for use on land as fertiliser.
Treatment line
- 01Equalisation tankBuffers flow, pollutant load and temperature after oil separation.
- 02Cooling towerBrings the feed down to about 35 °C for the anaerobic reactors.
- 03Dosing tankProvided to neutralise the feed, though no caustic was needed in operation.
- 04Two expanded granular sludge bed (EGSB) anaerobic reactorsSteel tanks 6 m wide and 16 m high, 847.8 m³ effective volume in total, run in parallel at about 35 °C with 9.8 days of retention; the biogas is cleaned and used to generate electricity.
- 05Dissolved air flotationRemoves suspended solids with a cationic polymer; half of the float sludge is returned to the anaerobic reactors.
- 06Biocontact aerobic tankAttached-growth aerobic tank with 48 hours of retention.
- 07Membrane bioreactorPolishes the aerobic effluent for more stable BOD removal before the ultrafiltration and reverse osmosis units.
What the source found
The anaerobic reactors removed most of the organic load and produced about 27.65 m³ of biogas per m³ of effluent, which was used to generate electricity; granular sludge gradually formed in the reactors after the polymer dose in the flotation unit was raised. COD fell by 99% and BOD by above 99% from the equalisation tank to the membrane bioreactor, and the aerobic effluent alone, after 3 hours of settling, already met the national BOD discharge standard, and the membrane bioreactor added little further COD removal. Reverse osmosis permeate was suitable as boiler feed water once dissolved oxygen is removed.
The plant ran 24 hours a day for one year, after a first year at 10 hours a day; the figures are averages of samples at the equalisation tank and at the membrane bioreactor outlet.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| BOD3 at 30 °C | BOD3 | mg/L | 30,314 | 13 | >99.9% |
| COD | COD | mg/L | 71,179 | 530 | 99.3% |
| Suspended solids | TSS | mg/L | 32,406 | not detectable | |
| Oil and grease | O&G | mg/L | 4,007 |
Inlet: equalisation tank after pretreatment. Outlet: membrane bioreactor outlet. Means with standard deviation of all samples over the year of continuous operation. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.