Aguato

    BOD and COD removal from slaughterhouse wastewater by sawdust carbon and a cloth-topped filter

    Raw wastewater from a private slaughterhouse on the Cairo to Ismailia desert road in Cairo Governorate, collected before it entered the local sewer, was treated in a laboratory model. The wastewater still contained blood and was used without dilution. It was screened to remove solids larger than 2 mm before the tests.

    Treatment line

    1. 01Mixing and adsorption on sawdust activated carbonCarbon made from sawdust activated with phosphoric acid, stirred with the wastewater in a 7 litre vessel for 100 minutes after adjusting the pH.
    2. 02SedimentationTwo hours of settling in the same vessel.
    3. 03Slow sand filter with a woven cotton layerA PVC pipe 10 cm in diameter with gravel and sand layers and one layer of woven cotton on top, fed at 50 litres per day.

    What the source found

    Over 30 days the full line removed about 95% of BOD, 92% of COD, 99% of suspended solids, 81% of dissolved solids, 83% of total nitrogen and 81% of phosphorus, and the filter stage improved every result. The treated water still did not meet the national discharge standard except for suspended solids, dissolved solids and phosphorus, which was put down to the blood in the raw water. The rough running cost was well below that of conventional treatment.

    Jar tests and batch runs set the carbon dose, contact time and pH, then the full line ran for 30 days with samples before mixing, after settling and after the filter.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH7.18
    BODBODmg/l4,53695%
    CODCODmg/l7,474.592%
    Total suspended solidsTSSmg/l42799.0%
    Total dissolved solidsTDSmg/l1,618.581%
    TurbidityNTU19697%
    Total phosphorusTPmg/l12.1881%
    Total nitrogenTNmg/l23383%
    Total coliform countColony/mL28,100,000,000,000300,000,000,00099%
    Faecal coliform countColony/mL127,0001,10099.1%

    Inlet: raw slaughterhouse wastewater used as feed. Outlet: outlet of the slow sand filter with the woven cotton layer. Inlet values are averages of the raw wastewater characterisation; removals are averages over 30 days of operation of the full laboratory line. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.