COD and suspended solids removal from gelatin wastewater by electrocoagulation and settling
A gelatin producer treats its effluent with an aluminium-based chemical coagulant. The effluent carries a heavy organic load and a large amount of suspended solids, which weaken the secondary treatment, so electrocoagulation was tested in the laboratory as an alternative to the chemical step.
Treatment line
- 01Electrocoagulation cellStirred 500 mL cell with aluminium plates 15 mm apart, run for 5 min at constant current.
- 02Settling in an Imhoff coneThe treated sample settled in a cone, with the settled solids read after 10 min and 2 h, and the clear liquid on top was analysed.
What the source found
Electrocoagulation removed 74% of COD, more than the plant's own coagulant at the same aluminium dose, and left lower turbidity and suspended solids. What remained was mostly dissolved COD, low enough to go on to biological treatment. Removal was best between slightly acid and slightly alkaline conditions, and the sludge contained zeolite-like crystals formed from the silicates in the water.
One sample of plant effluent was characterised, then split into untreated, chemically coagulated and electrocoagulated portions, which were settled and analysed; further tests varied the electrolysis time and pH.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 7.51 | ||||
| Turbidity | NTU | >1000 | 27.2 | ||
| Electrical conductivity | EC | μS/cm | 5,310 | ||
| Total suspended solids | TSS | mg/L | 5,520 | 84 | |
| Total dissolved solids | TDS | 3,186 | |||
| Soluble COD | sCOD | mg/L | 1,900 | 1,649 | 13% |
| Total COD | COD | mg/L | 6,600 | 1,742 | 74% |
| Total phosphorus | TP | mg/L | 64.8 | 25.4 | 61% |
| Total hardness as CaCO3 | TH | mg/L | 295 | ||
| Total alkalinity as CaCO3 | Alk | mg/L | 997.5 | ||
| Silicates (SiO4) | mg/L | 85.4 | 20.2 | 76% |
Inlet: gelatin plant effluent sample. Outlet: settled supernatant after electrocoagulation. One effluent sample, characterised raw and after 5 minutes of electrocoagulation and settling. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.