Arsenic and uranium removal from well water by softening and point-of-use reverse osmosis
A subdivision of nine homes in Homedale, Idaho, is supplied by one well with elevated arsenic, nitrate, uranium and vanadium. An under-sink reverse osmosis unit was installed in the kitchen of each home to treat softened water for drinking, and reject water goes to each home's septic system.
Treatment line
- 01Water softenerSoftens the intake water ahead of the reverse osmosis unit.
- 02Pre-filter cartridge
- 03Reverse osmosis elementOne thin-film composite element per home, rated at about 0.13 m³ a day, with a dissolved solids monitor and an automatic shut-off after a set volume.
- 04Storage tankA small tank of about 11 litres.
- 05Activated carbon post filter
What the source found
The softeners removed nearly all hardness, and the reverse osmosis units removed arsenic, uranium, vanadium and sulfate by more than 99%, nitrate by 90% and dissolved solids by 96%, bringing arsenic, nitrate and uranium well below their drinking water limits. Arsenic in the treated water stayed at trace level except in four samples. Reject water and energy use did not cause problems for the homes.
Monthly samples at the wellhead, after the softeners and after the reverse osmosis units at all nine homes over one year, with quarterly arsenic speciation at one home.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 7.3 | 6.6 | |||
| Total arsenic | As | μg/L | 57.8 | 0.4 | 99.3% |
| Arsenic(III) | As(III) | μg/L | 1.5 | 0.4 | 73% |
| Nitrate as nitrogen | NO3-N | mg/L | 10.2 | 1 | 90% |
| Total uranium | U | μg/L | 27.4 | <0.1 | |
| Total vanadium | V | μg/L | 32.4 | 0.2 | 99.4% |
| Sulfate | SO42− | mg/L | 167 | 0.6 | 99.6% |
| Silica | SiO2 | mg/L | 66.5 | 2.8 | 96% |
| Alkalinity as CaCO3 | Alk | mg/L | 295 | 12.4 | |
| Total dissolved solids | TDS | mg/L | 685 | 26.2 | 96% |
| Hardness as CaCO3 | TH | mg/L | 238 | 0.5 | 99.8% |
Inlet: raw well water at the wellhead. Outlet: treated water after the under-sink reverse osmosis units. Averages of monthly samples over one year at the wellhead and nine homes, with quarterly arsenic speciation at one home. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.