Hardness and iron removal from groundwater by aeration, filters and two ion exchange softeners
A small community water system in Illinois with 456 connections serving about 1,280 people treats very hard groundwater from three wells that also carries iron, arsenic and ammonia. The plant is rated at 1,050 m³ a day and runs 8 to 9 hours a day. It was built to remove iron, manganese, arsenic and hardness.
Treatment line
- 01Aeration
- 02Chlorine additionChlorine is added before the filters to oxidize iron, manganese and arsenic.
- 03Filters
- 04Two ion exchange softenersRegenerated with brine every 235 to 245 m³; part of the filtered water bypasses them and is blended back.
- 05Fluoride addition
- 06Polyphosphate addition
- 07Chlorine additionFinal disinfection of the blended water.
What the source found
The plant reduced hardness and removed most of the iron, manganese and arsenic, although finished water iron was sometimes above the secondary limit. The softeners at times removed most of the ammonia and at other times more than doubled it, and within one service cycle softener outlet ammonia rose and fell sharply over three hours. No free chlorine was found in the finished water, and the chloramine residual was sometimes very low, so ammonia should be considered when setting regeneration frequency, blending, or adding a separate ammonia treatment step.
Monthly samples of raw water and finished water (after blending and chlorination) over 6 months, with extra samples after a softener across one service cycle.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 7.35 | 7.59 | |||
| Alkalinity as CaCO3 | Alk | mg/L CaCO3 | 458 | 446 | |
| Hardness as CaCO3 | TH | mg/L CaCO3 | 314 | 124 | 61% |
| Calcium | Ca | mg/L | 73.1 | 28 | 62% |
| Magnesium | Mg | mg/L | 32 | 13.2 | 59% |
| Iron | Fe | mg/L | 2.8 | 0.27 | 90% |
| Manganese | Mn | mg/L | 0.029 | 0.012 | 59% |
| Arsenic | As | µg/L | 14.1 | 4.2 | 70% |
| Potassium | K | mg/L | 2.5 | 1.8 | 28% |
| Total ammonia nitrogen (free and combined in chloramines) | NH3-N | mg N/L | 2.93 | 2.13 | |
| Free ammonia nitrogen | NH3-N | mg N/L | 2.93 | 1.73 |
Inlet: raw well water. Outlet: finished water after blending of softened and bypass water and chlorination. Averages of 6 to 7 monthly samples over 6 months. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.