Aguato

    Iron and manganese removal from groundwater by aeration and manganese sand biofilters

    A drinking water plant in Harbin, northeast China, treats groundwater with high dissolved iron, manganese and ammonia. It opened in 1995 with a capacity of 10,000 m³ a day as a two-stage line of aeration and biofiltration, and was expanded to 40,000 m³ a day in 2004. Because the original aeration could not supply enough oxygen to oxidize all three pollutants, the water-dropping aeration unit was renovated and combined with the biofilters.

    Treatment line

    1. 01Water-dropping aerationRenovated to raise dissolved oxygen enough to oxidize the iron, manganese and ammonia.
    2. 02Manganese sand biofiltersBiofilters with a 1 m bed of manganese sand on a 0.75 m support layer, where a biofilm oxidizes iron, ammonia and manganese.

    What the source found

    Iron, manganese and ammonia in the treated water were all far below the drinking water standard, with ammonia removal of 74%, even though the water stayed below 7 °C. Most iron and ammonia were removed in the upper layer of the filter bed, where ammonia-oxidizing and nitrifying bacteria were enriched, while manganese was removed mainly in the deeper layers by a varied group of manganese-oxidizing bacteria. A stable biofilm grown from the groundwater's own microbes was judged to be the key to removing all three pollutants together.

    Dissolved iron, manganese, ammonia and oxygen were monitored over 30 days of stable operation, and sand was sampled at three depths in twenty biofilters for microscopy and microbial community analysis.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    Dissolved ironFemg/L9.4 to 15.7around 0.12
    Manganese (dissolved)Mnmg/L1.1 to 1.7around 6.0 x 10^-3
    AmmoniaNH374%
    pHabout 6.8about 6.8
    Temperature°Cbelow 7.0below 7.0
    Dissolved oxygenDOmg/L~ 1.5

    Inlet: raw groundwater. Outlet: effluent of the manganese sand biofilters. Monitoring over 30 days of stable operation; ranges and approximate values only. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.

    Similar references