Desalting reclaimed water for irrigation by nanofiltration, RO, evaporator and crystallizer
A municipal wastewater treatment plant in Larnaca, Cyprus, produces tertiary treated water after a membrane bioreactor that is reused for irrigation, but its high salinity is a risk to soil and crops. A zero liquid discharge pilot took part of this water, designed for 36 to 48 m³ per day, to produce low-salinity irrigation water and recover salts, and ran at the plant for two and a half years.
Treatment line
- 01Buffer tankStores part of the membrane bioreactor outflow before the feed pump.
- 02Cartridge filters5-micron filters to cut suspended solids ahead of the membranes.
- 03Acid dosingHydrochloric acid is dosed to the inflow to protect the membranes instead of adding antiscalant.
- 04NanofiltrationSix membranes in series at about 2 m³/h, separating divalent ions into the concentrate and passing mainly monovalent ions.
- 05Two-pass reverse osmosisTreats the nanofiltration permeate with four brackish-water membranes, the second pass treating the first-pass concentrate.
- 06Two-effect multi-effect distillation evaporatorWorks under vacuum with an electric boiler to concentrate the RO concentrate and produce distillate.
- 07Vacuum crystallizerHeat-pump unit that concentrates the evaporator brine to recover sodium chloride and also treated the nanofiltration concentrate, whose slurry was solar dried to mixed salts.
What the source found
The blended recovered water met the Cypriot standards for irrigation with reclaimed water, with sulfate removed by above 99% and chloride by 99%, and with nitrogen and phosphorus not detected. Reverse osmosis supplied most of the recovered water at low energy, while the evaporator and crystallizer used most of the energy; salt from the evaporator brine was not pure enough sodium chloride because nanofiltration let some divalent ions through, and the calcium-rich nanofiltration concentrate scaled the crystallizer.
Operating series on each unit over a pilot run of two and a half years, with the reported membrane data taken from selected three-week periods and the recovered water analysed after each stage and as a blend.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| Sodium | Na | mg/L | 490 | 14.95 | 97% |
| Potassium | K | mg/L | 43 | 1.8 | 96% |
| Magnesium | Mg | mg/L | 61 | 0.42 | 99.3% |
| Calcium | Ca | mg/L | 149 | 0.79 | 99.5% |
| Chloride | Cl− | mg/L | 890 | 10.77 | 99% |
| Sulfate | SO42− | mg/L | 500 | 0.59 | 99.9% |
| Total phosphorus | TP | mg/L | 1.52 | n.d. | |
| Total nitrogen | TN | mg/L | 10.4 | n.d. | |
| Electrical conductivity | EC | mS/cm | 4.2 | 47 μS/cm | |
| pH | 7.9 | 6.7 | |||
| BOD5 | BOD5 | mg/L | <1 | <1 | |
| COD | COD | mg/L | 20 | n.d | |
| Total suspended solids | TSS | mg/L | 7 | 0.2 | 97% |
| Total dissolved solids | TDS | mg/L | 29.3 |
Inlet: membrane bioreactor effluent feeding the pilot. Outlet: mixed recovered water from all stages. Inflow is an average characterisation of the feed; outlet is one analysis of the blended recovered water from the pilot run. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.