Water tools
Disinfection contactor: pipeline dispersion and serpentine basin t10
A contactor that lets some water through early gives that water less than its CT. Dispersion measures the spread; the higher the log goal, the less of it you can afford.
Within the allowance: close to plug flow.
How it works
Pipeline: diameter from the residence time, dispersion by the field-fitted relation:
Serpentine basin: dispersion from the aspect ratio and the ideality coefficient, and the t10 ratio from the aspect ratio:
- pipe diameter, m
- flow, m³/s
- residence time, s
- pipe length, m
- dispersion number
- friction factor
- coefficient of ideality
- basin length to width ratio
- time for the first tenth of a tracer to appear
The allowable dispersion is where a first-order process falls 5% short of its goal: about 0.03 at 1 log, 0.006 at 4 log. Regulators credit the t10, the time for the first tenth of a tracer to appear, which is conservative against a full residence-time model. Keep the flow-path width constant through 180 degree turns and add diffuser walls at inlet and outlet; up to 40% of a badly baffled tank can be dead volume. The t10 relation holds for aspect ratios of about 5 to 100.