    Chromium and solids removal from tannery wastewater by electrocoagulation and ozonation

    Wastewater from bovine hide chrome tanning was produced at a pilot tannery in Lima, Peru, and combined into one composite sample from the soaking, liming and unhairing, deliming, bating, pickling and tanning steps. The sample was treated in a small reactor and an ozonation tank to see whether the treated water could meet sewer discharge rules and how toxic it remained.

    Treatment line

    1. 01Electrocoagulation reactorA 16 by 16 by 20 cm cell with eight aluminium electrodes alternating as anodes and cathodes, run for 24 minutes to remove suspended solids and most contaminants.
    2. 02Ozonation tankThe clarified effluent was ozonated through perforated hose diffusers for 20 minutes to remove sulphides and break down resistant organic matter.

    What the source found

    The two steps together removed 96% of suspended solids, above 99% of chromium, 38% of COD and 31% of BOD, and almost all sulphides, but the treated water still exceeded the sewer discharge limits for organic matter, ammonium and aluminium. Ammonium rose after each step. Toxicity to lettuce fell after electrocoagulation but rose again after ozonation, so further treatment would be needed.

    The raw, electrocoagulated and ozonated samples were analysed by an accredited laboratory and tested for toxicity with lettuce seeds and earthworms.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    BODBODmg/L1,526.31,048.831%
    CODCODmgO2/L5,608.33,481.438%
    Total suspended solidsTSSmg/L1,8207696%
    Electrical conductivityECmS/cm22.521.4
    Fatsmg/L72.118.974%
    AmmoniumNH4+mg/L188.4364.1
    SulfideS2−mg/L110.810.002>99.9%
    ChlorideCl−mg/L5,353.84,628.714%
    AluminiumAlmg/L73.4613.8981%
    BariumBamg/L1.070.0496%
    CopperCumg/L0.20.0765%
    ChromiumCrmg/L107.880.2499.8%
    IronFemg/L5.10.9382%
    ManganeseMnmg/L0.180.0950%
    LeadPbmg/L0.050.002894%
    SodiumNamg/L5,181.484,700.429.3%
    ZincZnmg/L0.450.3229%
    TurbidityNTU1,675
    pH8.62
    Hexavalent chromiumCr(VI)mg/L<0.005

    Inlet: raw composite tannery effluent. Outlet: effluent after electrocoagulation and ozonation. One laboratory batch test on a composite effluent sample, analysed by an accredited laboratory. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.