Chromium removal from primary tannery effluent by a floating macrophyte in batch tanks
Effluent from a leather tannery in Asunción, already given primary treatment by coagulation and flocculation, was polished in small tanks planted with a floating macrophyte. The effluent as received carried little chromium, so trivalent chromium was added before the tests. The work asks whether local floating plants can lower chromium and toxicity in tannery water.
Treatment line
- 01Floating macrophyte tank (Eichhornia crassipes)Tanks holding 40 litres of effluent at 0.15 m depth, run as batches for 72 hours without aeration and stirred by hand every 6 hours, in triplicate beside a tank without plants.
What the source found
The floating macrophyte removed 54% of the chromium, 33% of COD and 14% of BOD, while ammonia rose slightly and total phosphorus did not fall. The chromium left was still above the national discharge limit, so other treatment before or after the plants would be needed. The plants lowered acute toxicity to water fleas and reduced the genotoxicity marker in fish.
Each tank was sampled at the start and the end of one 72 hour exposure, in triplicate, and the treated water was also tested for acute toxicity on water fleas and for genotoxicity in zebrafish.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| BOD5 | BOD5 | mg/L | 456 | 390 | 15% |
| COD | COD | mg/L | 657 | 443 | 33% |
| BOD/COD ratio | 0.69 | 0.88 | |||
| Total phosphorus | TP | mg/L | 0.65 | 0.66 | 0% |
| Ammonium nitrogen | NH4-N | mg/L | 60.11 | 67.55 | |
| Total Kjeldahl nitrogen | TKN | mg/L | 82.5 | 77.69 | |
| Sulfide | S2− | mg/L | 22.3 | 1.3 | 94% |
| Trivalent chromium | Cr(III) | mg/L | 12.34 | 54% | |
| Nitrite | NO2− | mg/L | 1.99 | ||
| Nitrate | NO3− | mg/L | <0.010 | ||
| Fats and oils | mg/L | <0.5 | |||
| pH | 8.5 | ||||
| Dissolved oxygen | DO | mg/L | 0.8 | ||
| Colour | Pt/Co | 150 | |||
| Total suspended solids | TSS | mg/L | 40 | ||
| Volatile suspended solids | VSS | mg/L | 33 | ||
| Settleable solids | mg/L | <0.010 | |||
| Cadmium | Cd | mg/L | <0.001 | ||
| Cyanide | CN− | mg/L | <0.002 | ||
| Copper | Cu | mg/L | 0.056 | ||
| Soluble iron | Fe | mg/L | 0.23 | ||
| Acute toxicity to water fleas (48 hours) | ATu | 3.11 | 2.15 | 31% |
Inlet: primary tannery effluent at the start of the batch, chromium spiked. Outlet: water in the water hyacinth tanks after 72 hours. Means of three replicate tanks sampled at the start and after one 72 hour batch. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.