    Polishing biologically treated coke plant wastewater by sand filtration and reverse osmosis

    The wastewater came from a coke plant in Silesia, southern Poland, with a capacity of 600,000 tonnes of coke a year, whose own treatment plant uses biological denitrification, nitrification and carbon oxidation. The biologically treated water still failed the national discharge standards, so samples were taken after the biological stage and given further treatment in the laboratory. Only this laboratory polishing line was studied.

    Treatment line

    1. 01Sand bed filterA 25 litre column with two gravel layers under a sand layer, 50 cm deep in total, used as pre-filtration.
    2. 02Reverse osmosisA high-pressure cross-flow test cell with one membrane of 144 cm² at 2.0 MPa, with the concentrate returned to the feed tank.

    What the source found

    Across the sand filter and reverse osmosis, COD fell by about 91%, total nitrogen by about 97% and suspended solids by about 99%. COD and total organic carbon were still above the national discharge standards after reverse osmosis, but the water was considered fit to return to the coke plant as technical water. Germination tests showed the biologically treated effluent was strongly toxic to broad bean seeds, while the reverse osmosis permeate was non-toxic or only slightly toxic.

    Samples of the biologically treated effluent taken from the plant's tank and run through the laboratory sand filter and reverse osmosis cell, with each indicator measured in four replicates, plus seed germination tests on the water after each step.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH7.27.4
    CODCODmg O2/L6,067.4567.391%
    Total nitrogenTNmg NH4+/L334.59.197%
    Total organic carbonTOCmg C/L411.135.291%
    Total carbonmg C/L717.554.193%
    Suspended solidsTSSmg/L132.61.199.2%
    Sum of 16 PAHsng/L94,730.075,571.7794%
    Naphthaleneng/L23,905.592,911.4888%
    Acenaphthyleneng/L115.9316.7186%
    Acenaphtheneng/L7,500.43490.9994%
    Fluoreneng/L302.5376.1775%
    Phenanthreneng/L107.9928.2174%
    Anthraceneng/L220.839.9996%
    Fluorantheneng/L564.3463.4589%
    Pyreneng/L899.4292.190%
    Benz(a)anthraceneng/L13,897.67762.0995%
    Chryseneng/L9,090.99859.391%
    Benzo(a)pyreneng/L5,891.467.3199%
    Benzo(b)fluorantheneng/L1,453.9490.3294%
    Benzo(k)fluorantheneng/L24,098.5596.0299.6%
    Dibenz(a,h)anthraceneng/L3,536.982.2199.9%
    Indeno(1,2,3-cd)pyreneng/L2,190.010.1>99.9%
    Benzo(ghi)peryleneng/L953.475.3299.4%

    Inlet: biologically treated coke plant effluent. Outlet: reverse osmosis permeate. Laboratory tests on one batch of effluent, four replicates per indicator. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.