Aguato

    COD and cyanide removal from coking wastewater in an aerobic fluidised-bed bioreactor

    An iron and steel works in Shexian, Hebei Province, treats its coking wastewater in a biological system of a first aerobic reactor, a hydrolytic reactor and a second aerobic reactor, built as two independent parallel lines and in operation for seven years. The system can handle about 2,400 m³ a day. The figures here cover only the first aerobic reactor, whose job is to remove most of the organic load and toxic compounds before the nitrogen removal stages.

    Treatment line

    1. 01First aerobic bioreactorInternal-loop airlift fluidised-bed activated sludge reactor of 3,600 m³ with about 60 hours hydraulic and 8 days sludge retention, run at 21 to 25 °C.

    What the source found

    The first aerobic reactor removed 90% of COD, 97% of BOD, 92% of sulfide and 98% of cyanide, and nearly all phenols, with no significant difference between the two lines. Oil did not fall. The dominant bacteria were groups linked to breaking down phenols, cyanide and aromatic compounds.

    Influent and effluent of the first aerobic reactor in both parallel lines were analysed during stable long-term operation, and activated sludge was sampled on different days in May 2018 for microbial sequencing.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    CODCODmg/L5,16749291%
    BODBODmg/L2015 in the north line, 1988 in the south line55 in the north line, 58 in the south line97%
    Phenolsmg/L987 in the north line, 1010 in the south line4.02 in the north line, 4.26 in the south line99.6%
    CyanideCN−mg/L390.998%
    ThiocyanateSCN−mg/L550 in the north line, 581 in the south line40 in the north line, 44 in the south line93%
    Total nitrogenTNmg/L462 in the north line, 489 in the south line423 in the north line, 444 in the south line
    Ammonium nitrogenNH4-Nmg/L98 in the north line, 97 in the south line78 in the north line, 75 in the south line
    Total phosphorusTPmg/L3.08 in the north line, 2.06 in the south line0.32 in the north line, 0.29 in the south line
    Total suspended solidsTSSmg/L300 in the north line, 283 in the south line41 in the north line, 38 in the south line
    Total organic carbonTOCmg/L995 in the north line, 1002 in the south line699 in the north line, 742 in the south line
    SulfideS2−mg/L14912.492%
    Oilsmg/L43 in the north line, 46 in the south line46 in the north line, 45 in the south line
    Polycyclic aromatic hydrocarbonsmg/L291 in the north line, 316 in the south line134 in the north line, 150 in the south line53%

    Inlet: wastewater entering the first aerobic reactor. Outlet: outlet of the first aerobic reactor. Means during stable long-term operation of the two parallel lines. Combined values are those printed in the text; where the source prints the two lines only separately, both values are given. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.

    Similar references