Aguato

    COD and BOD removal from household greywater by a horizontal flow constructed wetland

    Real greywater from the bathroom shower and sink, the kitchen sink and the washing machine of a house in Italy was treated to test it for reuse. After a laboratory test of three plant species, a larger pilot wetland of 200 litres was planted with the two chosen species and run indoors at about 25 °C under lamps. The water first settled in a tank upstream of the wetland, which is outside the sampled section.

    Treatment line

    1. 01Horizontal flow constructed wetland with submerged flowA 0.8 by 0.6 by 0.4 m bed of gravel and silica sand planted with two macrophyte species, run at a retention time of 1 day and then 3 days.

    What the source found

    At a 3 day retention time the wetland removed about 89% of COD, 92% of BOD and 92% of turbidity, with much lower nitrogen removal. Raising the retention time from 1 to 3 days gave little improvement except for phosphorus. The treated water suited drip irrigation of some crops and industrial reuse, but BOD and bacteria would need further treatment, such as disinfection or a longer retention time, for stricter uses like toilet flushing.

    Samples taken just before and just after the wetland over two phases of about seven weeks in total, one at a 1 day and one at a 3 day retention time; the figures are from the 3 day phase.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH8.38
    Electrical conductivityECµS/cm401.91,071.3
    TurbidityNTU66.25.292%
    Total suspended solidsTSSmg/L49.7884%
    CODCODmg/L1,11911989%
    BOD5BOD5mg/L255.720.692%
    Total nitrogenTNmg/L116.145%
    Nitrite nitrogenNO2-Nmg/L0.30.1
    Nitrate nitrogenNO3-Nmg/L0.93.8
    Total Kjeldahl nitrogenTKNmg/L10.31.9
    Total phosphorusTPmg/L2.3157%
    Escherichia coliUFC/100 mL2.4 × 10^5937

    Inlet: greywater entering the constructed wetland. Outlet: outlet of the constructed wetland. Means of samples taken during the pilot phase run at a 3 day retention time. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.

    Similar references