Aguato

    COD and phenol removal from olive mill wastewater by two-step coagulation and carbon filtering

    Wastewater from a modern three-phase olive mill in the Koura Valley of North Lebanon, an acidic, strongly coloured effluent with very high organic load that mills in the country often dump untreated. Samples were treated in beakers and small filter columns to find a simple process that could make the effluent fit for irrigating olive orchards.

    Treatment line

    1. 01CentrifugationRemoves part of the solids before chemical treatment.
    2. 02Dilution with olive washing waterFour parts mill wastewater mixed with one part of the mill's olive washing water.
    3. 03First coagulation and flocculationLime then alum added, fast and slow mixing, then 12 hours of settling.
    4. 04Second coagulation and flocculationA second, lower dose of lime and alum on the settled water, again followed by settling.
    5. 05Activated carbon and gravel filterA 30 cm column of activated carbon mixed with gravel, chosen from three filter designs as the best performer.

    What the source found

    The full line, dilution included, cut COD by 92% and removed most of the turbidity, colour and the main phenolic compounds. The second coagulation step had a higher COD reduction rate than the first, and the activated carbon and gravel filter did better than the other two filter designs. The sludge from the first coagulation step had a heating value high enough to be considered as a substitute fuel, and the treated water was proposed for spreading on olive groves.

    Laboratory tests on mill samples, with several coagulant doses and three filter designs compared, and the best conditions repeated and analysed at each step.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH4.838.82
    Total solidsTS% w/v6.710.7289%
    Electrical conductivityECmS/cm8.913.69
    CODCODg/L135.6310.7692%
    TurbidityNTU27.40.2899.0%
    Colour (absorbance at 436 nm)390.720.0695%
    Ash% m/v0.910.2573%
    LeadPbμg/L61.524.3293%
    IronFeμg/L7.742.4568%
    AluminiumAlμg/L16012025%
    Gallic acidμmol/L< LD<LD
    Vanillyl alcoholμmol/L3571097%
    Tyrosolμmol/L2,06715693%
    Vanillic acidμmol/L1241191%
    p-Coumaric acidμmol/L1111091%

    Inlet: raw olive mill wastewater. Outlet: outlet of the activated carbon and gravel filter. Laboratory runs at the best coagulant doses; raw water n = 2 and filtered water n = 5 (n = 3 for phenolic compounds). Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.