    Iron and chromium removal from iron ore process water by electrocoagulation

    Process water from an iron ore beneficiation plant in Odisha state, India, carries dissolved metals and very high suspended solids. About 100 litres were brought to a laboratory, left to settle for two days and passed through filter paper, then treated to test whether electrocoagulation can make the water fit for reuse or safe to discharge.

    Treatment line

    1. 01Electrocoagulation cell1 litre batches in a stirred beaker with two aluminium plate electrodes 1 cm apart in monopolar mode, run for 60 minutes, with sodium chloride added to raise conductivity.
    2. 02Filtration of treated waterSamples of the treated water were passed through filter paper before analysis.

    What the source found

    Aluminium electrodes in a simple two-plate layout gave the best overall result, removing above 99% of iron and above 99% of chromium in 60 minutes, and the treated water met drinking-water guideline values for the metals and salts measured. Higher current density removed metals faster but raised energy use and residual aluminium, so a moderate setting using about 3.9 kWh per m³ was chosen. Analysis of the sludge showed that many trace metals were also captured.

    Batch tests, each repeated three times, on the settled and filtered water, comparing electrode materials, electrode layouts, current densities, electrode spacing and conductivity, with samples every 10 minutes; the figures are from the chosen operating conditions.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    IronFemg/L115.24>99.9%
    ChromiumCrmg/L7.199.5%
    CopperCumg/L0.270.0774%
    LeadPbmg/L2.6899.3%
    ManganeseMnmg/L0.9698%
    AluminiumAlmg/L24.750.7297%
    SilicaSiO2mg/L1.29
    Total dissolved solidsTDSmg/L130.685.4535%
    Total suspended solidsTSSmg/L43,693
    TurbidityNTU9770.8999.9%
    Electrical conductivityECµS/cm178.3522
    ResistivityKΩ4.566
    Salinitymg/L95.3692.612.9%
    pH7.097.36

    Inlet: settled and filtered process water, before salt was added for the electrocoagulation run. Outlet: treated water after 60 minutes of electrocoagulation with aluminium electrodes. Batch tests repeated three times; aluminium anode and cathode, 68.50 A/m2, 1 cm spacing, 60 minutes. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.