Aguato

    Ammonia recovery from pig manure liquid by air stripping and sulphuric acid scrubbing

    The manure processing plant of a pig farm in Hooglede, Belgium, in operation since 2011 with a maximum capacity of 52,000 tonnes a year. Raw manure is split by a decanter centrifuge with polymer dosing, and part of the nitrogen-rich liquid fraction, on average 29 tonnes a day, passes through the ammonia stripping and scrubbing unit studied here before it is mixed with unstripped liquid and treated in a nitrification-denitrification tank. The unit recovers an ammonium sulphate solution as a fertiliser product and lowers the nitrogen load on the biological stage.

    Treatment line

    1. 01Two vertical stripping columns2.5 m by 3 m by 2 m each, packed with pall rings and fed by 9 spray nozzles, sharing an air flow of 1,440 m³/h; no caustic soda or lime is added, and the liquid becomes more alkaline as carbon dioxide is vented.
    2. 02Scrubbing column2.5 m by 3 m by 2.5 m; the ammonia-laden air meets dilute sulphuric acid and forms an ammonium sulphate solution.

    What the source found

    The unit removed 57% of ammonium nitrogen and 36% of total nitrogen from the liquid fraction, recovering it as an ammonium sulphate solution, while COD fell by only 6% and phosphorus did not fall. Sulphuric acid gave slightly better ammonium removal than nitric acid, which needed a lower air flow. With the stripping step the plant processed more raw manure a day than before.

    Inlet and outlet samples of the liquid fraction over one year of operation, from March 2022 to March 2023, with a nitrogen mass balance of the unit.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH8.18.5
    Electrical conductivityECmS/cm31.330.1
    CODCODg/kg55.452.16.0%
    Total nitrogenTNg/kg5.823.7336%
    Ammonium nitrogenNH4-Ng/kg3.731.6157%
    PhosphorusPg/kg0.310.320%

    Inlet: liquid manure fraction entering the stripping unit. Outlet: stripped liquid fraction leaving the stripping unit. Means over one year of operation, March 2022 to March 2023, with sulphuric acid scrubbing. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.

    Similar references