Landfill leachate treatment by reverse osmosis with second-hand seawater desalination membranes
The leachate treatment plant of a non-hazardous waste landfill in Catalonia, with a maximum capacity of 50 m³/day. Leachate is first treated in a pressurised external cross-flow membrane bioreactor with nitrification and denitrification, and the ultrafiltered water then goes either to activated carbon or to the reverse osmosis stage studied here. Spent seawater desalination membranes, reused directly or after chemical regeneration, replaced half of the reverse osmosis membranes, and the permeate was reused on the landfill site.
Treatment line
- 01Sulphuric acid and antiscalant dosingAdded ahead of reverse osmosis to prevent scaling.
- 02Reverse osmosisTwelve spiral-wound modules in four pressure vessels in one stage, historically run at about 47 bar on 1.2 m³/h of feed.
What the source found
The second-hand membranes ran for up to 27 months with permeate quality similar to the plant's standard membranes and within the discharge limits. With half the system on second-hand membranes, the stage ran at lower pressure and higher recovery than in the previous four years, helped partly by less salty feed. One regenerated module failed after 10 months because of a detached end cap, which showed up as yellow permeate with more organic matter.
Continuous logging of pressure and flows from November 2019 to February 2022, compared with four previous years of operation, plus 6 to 12 permeate samples from each pressure vessel.
What it removed
| Parameter | Symbol | Removal |
|---|---|---|
| COD | COD | 98% |
| Chloride | Cl− | 96% |
| Nitrate nitrogen | NO3-N | 84% |
| Ammonium nitrogen | NH4-N | 59% |
Inlet: ultrafiltered landfill leachate fed to reverse osmosis. Outlet: reverse osmosis permeate. Rejections from the facility historic data for 2016 to 2019 with the standard membranes; no feed or permeate values printed for that period. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.