BOD and ammonium removal from young landfill leachate by intensive aeration
A controlled landfill that takes household waste from the Mohammedia and Benslimane prefectures receives about 565 tonnes of waste a day and collects about 70 m³/day of young, highly biodegradable leachate in storage tanks. Its existing treatment uses lime, coagulant, acid and oxidant dosing and a reed-planted sand filter. This test on site checked whether forced aeration alone could cut the organic and nitrogen load.
Treatment line
- 01Aerated tank with bubble air diffuserA 1 m³ open polyethylene tank filled with raw leachate from the main storage tank, with compressed air blown in at the bottom 12 hours a day for 30 days at ambient temperature.
What the source found
Over 30 days of aeration BOD fell by 98%, COD by 73% and ammonium by 85%, and the remaining leachate was much less biodegradable. The cost of electricity for aeration was named as the main limit on using the method.
One raw sample from the storage tank, then weekly samples from the aerated tank over the 30-day batch. The removal figures compare the raw sample with the last weekly sample.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| COD | COD | mg O2/L | 38,600 | 10,520 | 73% |
| BOD5 | BOD5 | mg O2/L | 24,000 | 400 | 98% |
| pH | 7.62 | 9.46 | |||
| Electrical conductivity | EC | mS/cm | 48.4 | 29.9 | |
| Suspended solids | TSS | mg/L | 4,620 | 6,680 | 0% |
| Nitrate nitrogen | NO3-N | mg/L | 33.14 | 30.6 | 7.7% |
| Ammonium as the ion | NH4+ | mg/L | 4,700 | 720 | 85% |
| Total Kjeldahl nitrogen | TKN | mg/L | 5,932.45 | 1,255.43 | |
| Phosphorus | P | mg/L | 34 | <0.5 | |
| Phenol | mg/L | 0.11 | 0.13 | 0% | |
| Chloride | Cl− | mg/L | 6,204.27 | 9,217.78 | 0% |
Inlet: raw leachate from the storage tank. Outlet: leachate in the aerated tank in the last week of the batch. One raw sample, then weekly samples over a 30-day batch aeration; the outlet is the last weekly sample. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.