Aguato

    Ammonium and COD removal from landfill leachate by aerated and anoxic activated sludge reactors

    A medium-sized sanitary landfill on a Greek island, serving about 50,500 permanent inhabitants and in operation since 2012, treats its leachate on site, about 25 m³/day during the study. After the settling tank the plant also has a chlorination tank and a final effluent tank, which were outside the sampled section.

    Treatment line

    1. 01Raw leachate storage tankHolds the incoming leachate before biological treatment.
    2. 02Two aerated activated sludge bioreactors in seriesDiffuser aeration was adjusted during the study to improve nitrification.
    3. 03Anoxic bioreactorA third reactor operated under anoxic conditions; from September 2020 it also received 10 m³/day of raw leachate to improve denitrification.
    4. 04Settling tank with sludge recirculationSludge recirculation was raised from 10 to 50 m³/day in March 2020.

    What the source found

    Over the year the plant removed about 56% of COD, 42% of suspended solids and 95% of ammonium nitrogen, and ammonium removal improved after sludge recirculation and aeration were adjusted. Only a small part of the organic load was biodegradable, and the treated leachate did not meet the requirements for discharge or reuse on COD and BOD. Constructed wetlands followed by evaporation ponds were proposed as a low energy route to zero discharge.

    Eighty grab samples at the raw leachate storage tank and the settling tank outlet in 11 monthly campaigns from February 2020 to February 2021.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH8.348.21
    Electrical conductivityECmS/cm12.129.16
    Total suspended solidsTSSmg/L553242%
    CODCODmg/L3,5851,58356%
    BODBODmg/L25447
    BOD/COD ratio0.080.03
    Ammonium nitrogenNH4-Nmg/L7223595%
    Nitrate nitrogenNO3-Nmg/L179.7
    Phosphate as phosphorusPO4-Pmg/L8.210.7

    Inlet: raw leachate storage tank. Outlet: outlet of the settling tank after the activated sludge reactors. Means of 40 grab samples per point taken from February 2020 to February 2021. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.