    BOD and COD removal from hospital wastewater by a packaged moving bed biofilm reactor

    A teaching hospital in Baquba treats its raw wastewater in a packaged plant with a capacity of 250 m³/day. Hospital wastewater carries pathogens and harmful substances such as pharmaceuticals and disinfectants. The package also includes tertiary filtration and ultraviolet disinfection, but the figures reported are for the moving bed biofilm system.

    Treatment line

    1. 01Collection and equalisation basinHolds the raw hospital wastewater; a feed pump here delivers it to the plant.
    2. 02Screen0.75 cm openings on the raw wastewater.
    3. 03First moving bed biofilm reactorRoughing chamber that takes peak loads and removes most of the BOD, aerated by coarse bubbles with free-floating plastic carriers filling half the tank.
    4. 04Second moving bed biofilm reactorPolishing chamber, also aerated with floating carriers.
    5. 05Integral clarifierSettles suspended solids to a sludge tank and returns biomass and residual BOD to the first chamber.

    What the source found

    Despite a fluctuating inlet load, the system removed on average 80% of BOD, 75% of COD and 78% of suspended solids, and about 79% of the ammonia was nitrified. Total nitrogen removal was low because there is no anoxic zone, and dissolved solids hardly changed. Little biomass grew on the carriers, likely due to the low organic load, but the sludge settled well, and the effluent was judged suitable for the river protection requirements for organic matter and suspended solids.

    Weekly tests of the raw wastewater drawn from the equalisation basin and of the system effluent from January to mid April 2017, each value the average of three samples, at a flow of 6 m³/h and a hydraulic retention time of 4.1 hours.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    BOD5BOD5mg/l147.228.481%
    CODCODmg/l194.646.776%
    PhosphatePO43−mg/l2.8
    Ammonium nitrogenNH4-Nmg/l51.3
    Nitrate nitrogenNO3-Nmg/l1.73
    Total suspended solidsTSSmg/l13529.678%
    Oil and greaseO&Gmg/l7.5
    pH8
    Electrical conductivityECµS1,855
    SulfateSO42−mg/l173
    Total dissolved solidsTDSmg/l1,117

    Inlet: raw hospital wastewater from the equalisation basin. Outlet: effluent of the moving bed biofilm system. Weekly tests from January to mid April 2017, each the average of three samples. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.