BOD and COD removal from hospital wastewater by a combined anaerobic and aerobic biofilter
The wastewater treatment unit of a hospital, which treats the hospital's liquid waste before it is discharged to a receiving water. The plant combines anaerobic and aerobic treatment in a biofilter reactor with blower aeration and honeycomb biofilm media.
Treatment line
- 01Coarse screening
- 02Comminutor
- 03Equalisation
- 04Sedimentation
- 05Combined anaerobic and aerobic biofilter reactorHoneycomb biofilm media with continuous air supply from a blower; no filter is fitted inside the tanks.
- 06Chlorination
- 07Holding tank
What the source found
The treated water met the discharge standard for BOD, COD and suspended solids. Mean removal was 93% for BOD and 86% for COD, a significant drop, while the fall in suspended solids was not statistically significant, which is put down to the lack of a filter in the treatment tanks.
Inlet and outlet values for each month from April to June 2016, compared by analysis of variance.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| BOD | BOD | mg/l | 163.6 | 11.24 | 93% |
| COD | COD | mg/l | 276.67 | 40 | 86% |
| Total suspended solids | TSS | mg/l | 31.27 | 16.67 |
Inlet: wastewater entering the biofilter unit. Outlet: effluent of the biofilter unit. Means of the monthly values for April, May and June 2016. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.