COD and nitrogen removal from bloody poultry slaughter wastewater by electrocoagulation
A poultry slaughterhouse in Sakarya produces about 2,500 m³ of wastewater a day. Wastewater taken from its stabilisation pool, with blood added at 1% by volume to match the plant's daily blood release, was treated in the laboratory as a pretreatment ahead of biological treatment. Electrocoagulation was picked first by comparing it on paper with coagulation, dissolved air flotation and anaerobic treatment.
Treatment line
- 01Batch electrocoagulation reactorA stirred 500 mL glass cell with four bipolar aluminium or iron electrodes, treating 200 mL per run with salt added as electrolyte.
- 02CentrifugationEach treated sample was centrifuged before analysis.
What the source found
At the best settings, a five-minute run with aluminium electrodes removed about 82% of COD, 83% of total nitrogen and 79% of oil and grease, better than iron electrodes. Electrocoagulation was judged a workable way to cut the load sent on to secondary treatment, with potential for larger-scale use.
Triplicate batch runs varying salt dose, pH, current density and reaction time for aluminium and iron electrodes.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| COD | COD | mg L-1 | 9,300 | 82% | |
| Total organic carbon | TOC | mg L-1 | 2,634 | 82% | |
| Oil and grease | O&G | mg L-1 | 2,300 | 79% | |
| Total phosphorus | TP | mg L-1 | 9.1 | ||
| Total nitrogen | TN | mg L-1 | 1,240 | 83% | |
| pH | 6.7 |
Inlet: slaughterhouse wastewater with 1% blood added, before electrocoagulation. Outlet: treated sample after electrocoagulation with aluminium electrodes and centrifugation. Laboratory batch runs at the optimum conditions; the source prints removals only, no treated concentrations. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.