    BOD and suspended solids removal from poultry slaughterhouse wastewater by SBR with fibres

    A poultry slaughterhouse in Nibong Tebal, Penang, has a capacity of 13,000 birds a day and produces about 140 tonnes of wastewater daily from cutting, chilling, scalding, packing and cleaning. The wastewater was taken from its final collection tank, after the internal organs and feathers are screened out, and treated in laboratory reactors to test fibres as carriers for the biomass.

    Treatment line

    1. 01Sequencing batch reactor with submerged fibres60 L working volume seeded with activated sludge, fed 21 L a day on a 24 h cycle of 30 min filling, 20 h aeration and 3 h settling before decanting, with yarns of jute, acrylic and polyester fibre submerged in the tank as carriers for the biomass.

    What the source found

    Every reactor with fibres removed more than the reactor without fibres. At its best, the reactor with all three fibres removed 96% of BOD, 96% of suspended solids and 77% of oil and grease. The best treated water from the fibre reactors met the national discharge limits for BOD and COD.

    Wastewater collected twice a week over about ten months was run through daily cycles in reactors with each fibre type, with a combination of all three and with no fibre. BOD, COD and ammonia were tested daily.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    BODBODmg/L4096%
    CODCOD90%
    Ammonia nitrogenNH3-Nmg/L10696%
    PhosphatePO43−79%
    NitriteNO2−71%
    NitrateNO3−93%
    Total suspended solidsTSS96%
    Oil and greaseO&G77%

    Inlet: slaughterhouse wastewater fed to the reactor. Outlet: decanted effluent of the reactor with all three fibres. Maximum removal efficiencies of the reactor with all three fibres over its daily cycles. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.