Aguato

    Suspended solids and turbidity removal from leek washwater by electrocoagulation

    A farm in Quebec washes leeks grown on clay loam. Its washwater goes through a settling tank and then a non-aerated lagoon with a residence time of 2 hours; the samples were taken at the settling tank outlet, before the lagoon, and treated in the laboratory. The farm's own tank and lagoon were not part of the test.

    Treatment line

    1. 01Batch electrocoagulation cellA 0.5 litre cell with two aluminium plate electrodes 1 cm apart, run for 8.8 minutes at the settings optimised on another farm's water.
    2. 02SettlingOne hour of settling, after which the clear upper layer was analysed.

    What the source found

    Electrocoagulation removed above 99% of suspended solids, 98% of turbidity, 72% of COD and above 99% of iron, and suspended solids were well within the provincial discharge limit. The two insecticides found in the raw water were fully removed.

    Settling tank outlet samples were treated in the laboratory cell and the raw water and the settled treated water were analysed; values are means with standard deviations.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH6.57.5
    TurbidityNTU1,1052298%
    Total suspended solidsTSSmg/L2,193899.6%
    CODCODmg/L972772%
    Total phosphorusTPmg/L< 0.55< 0.55
    Aluminium (Al3+)Al3+mg/L120.596%
    Iron (Fe3+)Fe3+mg/L140.0599.6%
    Thiamethoxamµg/L0.020>99.9%
    Clothianidinµg/L0.10>99.9%

    Inlet: leek washwater taken at the settling tank outlet. Outlet: clear upper layer after electrocoagulation and one hour of settling. Laboratory batch electrocoagulation at 0.32 A for 8.8 minutes; means with standard deviations. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.