COD and BOD removal from poultry abattoir wastewater by extended-aeration activated sludge
The wastewater treatment station of a poultry slaughterhouse in the interior of Pernambuco state. It is one of six activated sludge plants in the state that were sampled to relate treatment results to the microorganisms in the sludge.
Treatment line
- 01Grit chamberInlet samples were taken where the wastewater enters it.
- 02Extended-aeration activated sludge tankSludge samples were taken here to identify the microorganisms.
- 03Secondary clarifierOutlet samples were taken at its exit.
What the source found
On the second visit the plant removed about 95% of COD, 90% of suspended solids and 93% of colour, and turbidity fell by more than 90%. BOD and ammonia results met the national discharge rule. The sludge held few kinds of microorganisms, which may be linked to organic levels at the outlet that were still fairly high despite the large removals.
Samples at the inlet and outlet, taken at the same moment, on two dry-season dates in 2015, in March and August.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| COD | COD | mg O2/L | 5,100 | 250 | 95% |
| BOD5 | BOD5 | mg O2/L | 1,250 | 40 | 97% |
| Total solids | TS | mg/L | 1,861 | 961 | 48% |
| Fixed solids | FS | mg/L | 686 | 831 | 0% |
| Volatile solids | VS | mg/L | 1,175 | 130 | 89% |
| Total suspended solids | TSS | mg/L | 1,252 | 120 | 90% |
| Fixed suspended solids | FSS | mg/L | 463 | 35 | 92% |
| Volatile suspended solids | VSS | mg/L | 789 | 85 | 89% |
| Ammonia nitrogen | NH3-N | mg/L | 1.42 | 0.36 | |
| Nitrate nitrogen | NO3-N | mg/L | 5 | 2.64 | |
| Electrical conductivity | EC | µS/cm | 1.86 | 2.07 | |
| Colour | mg Pt-Co/L | 4,700 | 341 | 93% | |
| pH | 7 | 7 | |||
| Turbidity | NTU | 1,072 | 65.4 | 94% |
Inlet: grit chamber inlet. Outlet: secondary clarifier outlet. One inlet sample at the grit chamber and one outlet sample after the secondary clarifier, taken at the same moment in August 2015, in the dry season. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.