PFAS removal from landfill leachate by continuous foam fractionation
Leachate from a landfill in Uppsala was drawn in real time from the inflow to the landfill's own treatment plant and fed to a pilot foam fractionation column on site. Landfill leachate is often contaminated with PFAS, and a low-cost way to take them out was needed. Leachate from the part of the landfill where municipal sewage sludge is stored was not included.
Treatment line
- 01Influent vesselA 300 L vessel mixed by the incoming leachate, from which a pump fed the column at a steady rate.
- 02Foam fractionation columnA 19 cm wide column with the water surface 1.63 m above the bottom, air blown in through four diffusers at the base, and the foam carrying the PFAS collected at the top; contact time 10 to 30 minutes.
What the source found
Total PFAS removal levelled off at about 60%, while long-chain compounds were removed far better: on average 95% for PFOS and 92% for PFOA, against no removal of PFBA and about 10% for PFBS. Shorter contact time, less air and a smaller foam fraction all lowered removal, and batch operation was no better than continuous operation. Apart from dissolved organic carbon, iron and aluminium collecting in the foam, the treatment did not change the general chemistry of the leachate; the foam, about a tenth of the inflow, still needs further treatment.
Sixteen continuous two-hour runs, a shorter preliminary run and a batch test, varying contact time, air flow and the share of water removed as foam, with influent, effluent and foam sampled four times per two-hour run; general chemistry was analysed on four influent and four effluent samples.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| Dissolved organic carbon | DOC | mg/L | 36 | 36 | 0% |
| Phosphorus | P | µg/L | 140 | 120 | |
| Calcium | Ca | mg/L | 150 | 150 | |
| Manganese | Mn | µg/L | 520 | 530 | 0% |
| Sodium | Na | mg/L | 710 | 710 | |
| Potassium | K | mg/L | 240 | 240 | |
| Iron | Fe | mg/L | 5.3 | 4.8 | 9.4% |
| Aluminium | Al | µg/L | 27 | 25 | 7.4% |
| Copper | Cu | µg/L | 54 | 28 | |
| Magnesium | Mg | mg/L | 56 | 57 | |
| COD (permanganate) | CODMn | mg/L | 27 | 29 | |
| Ammonium | NH4+ | mg/L | 59 | 60 | |
| Nitrate | NO3− | mg/L | 18 | 18 | |
| Chloride | Cl− | mg/L | 920 | 910 | |
| Sulfate | SO42− | mg/L | 130 | 120 | |
| Electrical conductivity | EC | mS/m | 440 | 450 | |
| pH | 7.9 | 8 | |||
| Alkalinity | Alk | mg/L | 1,300 | 1,300 | |
| Total organic carbon | TOC | mg/L | 36 | 34 |
Inlet: landfill leachate in the influent vessel feeding the column. Outlet: treated effluent from the foam fractionation column. Means of four influent and four effluent samples taken on test dates. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.