Aguato

    Solids removal from tequila vinasse by polyacrylamide flocculation and a rotating screen

    A tequila distillery producing 7,000 to 8,000 litres of tequila a day generates 75 to 80 m³ of hot, acidic vinasse a day from four stills. The pilot work was done to set the operating conditions for rehabilitating the distillery's vinasse treatment plant. The treated vinasse still has to be neutralised or sent to a further process, and the recovered flocs are meant for composting with agave bagasse.

    Treatment line

    1. 01Vinasse collection pitAerated pit where the vinasse is homogenised before being pumped to the flocculation tank.
    2. 02Coagulation and flocculation tank798-litre stainless steel tank with a conical bottom, dosed with a cationic polyacrylamide flocculant while mixed by air, then left to settle for 45 minutes.
    3. 03Rotating cylindrical screen separatorDrum with a 0.2 mm mesh turning at 12 rpm that separates the flocs from the liquid.
    4. 04Treated vinasse tank327-litre stainless steel tank collecting the screened liquid.

    What the source found

    Higher flocculant doses removed more solids and COD and recovered more flocs per volume of vinasse. In the run with the highest dose, suspended solids fell by 86% and COD by 51%, while dissolved solids fell by only 8%. Flocculated vinasse needed less alkali to neutralise, and quicklime was cheaper than caustic soda for this step; too much flocculant gave sticky, weak flocs.

    Laboratory tests at seven flocculant doses, then six pilot batch runs at four doses, with samples of the vinasse in the flocculation tank before dosing and of the liquid after treatment in each run. The figures are from one run, at the highest dose.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH3.83.8
    Temperature°C55not determined
    Settleable solidsmL/L9506493%
    Total solidsTSmg/L39,63023,51941%
    Total suspended solidsTSSmg/L16,7252,36586%
    Total dissolved solidsTDSmg/L22,90521,1547.6%
    CODCODmg/L71,83535,25951%

    Inlet: vinasse in the flocculation tank before dosing. Outlet: supernatant liquid after the flocculant treatment. One pilot batch run at a flocculant dose of 800 mg/L. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.