Aguato

    Suspended solids and metals removal from road runoff by a planted soil biofilter

    A planted biofilter in a green infrastructure demonstration park in Milwaukee, Wisconsin, treats rain runoff from a stretch of asphalt feeder street serving an industrial area. The sewerage authority wants to cut runoff volume and the solids, phosphorus, metals and chloride reaching local waters. Water leaving the biofilter goes to an underground cistern that stores it for irrigating the park's vegetation.

    Treatment line

    1. 01Pretreatment forebayLined pit filled with cobble over coarse gravel that the runoff fills before overflowing into the biofilter.
    2. 02Planted biofilterAbout 110 m² bed with native plants and about 0.6 m of engineered soil made of topsoil, sand and compost, with a shallow ponding zone above.
    3. 03Gravel storage layer with underdrainCoarse aggregate layer on an impermeable liner that holds the filtered water before a perforated underdrain pipe carries it away.

    What the source found

    The biofilter cut runoff volume and peak flow sharply and retained most particle-bound pollutants: median concentrations fell from inlet to outlet for suspended solids, total phosphorus and most total metals, including a 97% drop for lead. Dissolved phosphorus and several dissolved metals, as well as sodium, came out at higher concentrations than they went in, which was linked to the organic-rich soil, changing oxygen conditions and winter road salt. Soil media with less organic matter and more adsorbing capacity were suggested to improve removal of dissolved pollutants.

    Automatic flow-weighted composite samples taken at the pipe entering the biofilter and at the underdrain outlet, giving 19 paired storm events from 2022 to 2024, with flows measured at both points.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    Total suspended solidsTSSmg/L3439
    CalciumCamg/L46.4965.23
    MagnesiumMgmg/L18.7710.942%
    SodiumNamg/L3.186.76
    BromideBr−mg/L<0.01<0.01
    ChlorideCl−mg/L4.114.55
    Total phosphorusTPmg/L0.420.1271%
    Dissolved phosphorusmg/L0.050.06
    pH7.87.87
    Total aluminiumAlµg/L4,830.95211.1796%
    Total cadmiumCdµg/L0.290.0679%
    Total chromiumCrµg/L11.331.6186%
    Total cobaltCoµg/L5.250.5789%
    Total copperCuµg/L23.799.4660%
    Total ironFeµg/L7,989.74457.0594%
    Total leadPbµg/L35.910.9597%
    Total manganeseMnµg/L265.2648.3582%
    Total nickelNiµg/L13.513.2676%
    Total vanadiumVµg/L11.511.2289%
    Total zincZnµg/L127.1315.588%
    Total arsenicAsµg/L1.852.06
    Dissolved aluminiumAlµg/L55.4825.9253%
    Dissolved cadmiumCdµg/L<0.030.05
    Dissolved chromiumCrµg/L1.221.32
    Dissolved cobaltCoµg/L0.090.39
    Dissolved copperCuµg/L2.819.1
    Dissolved ironFeµg/L33140.8
    Dissolved leadPbµg/L0.20.24
    Dissolved manganeseMnµg/L7.7638.14
    Dissolved nickelNiµg/L0.823.7
    Dissolved vanadiumVµg/L1.740.8352%
    Dissolved zincZnµg/L6.0512.4
    Dissolved arsenicAsµg/L0.381.9

    Inlet: road runoff in the pipe entering the biofilter. Outlet: underdrain outlet of the biofilter. Medians of event mean concentrations from 19 paired storm events, 2022 to 2024. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.