Suspended solids and phosphorus removal from residential stormwater by media filter cartridges
A townhouse complex at Ormiston, about 28 km east of Brisbane in Southeast Queensland and within 1 km of a sensitive bay, has a site of 2028 m² that is mostly roof and concrete driveway. Its stormwater passes a treatment train of rainwater tanks on the roofs and mesh baskets in the grated inlet pits before reaching an underground filter vault, which also holds the water back before it is released to the council drains. The figures here cover the filter vault only.
Treatment line
- 01Media filter cartridges in detention vaultTwo 850 mm high cartridges filled with perlite, zeolite and activated alumina, installed in an underground concrete vault of 4 m³.
What the source found
The media filters lowered suspended solids by 79%, total nitrogen by 42%, copper by 47% and zinc by 55% across the sampled storms, with all differences between inlet and outlet statistically significant. The water reaching the filters was relatively clean compared with local guideline values, and removal was better when inlet concentrations were higher. After about 58 months of operation with yearly vacuum cleaning of the vault, the cartridges showed no sign of solids or phosphorus breakthrough.
Flow-weighted composite samples at the inlet and outlet of the media filters for 15 qualifying storm events between 2014 and 2017, with copper and zinc added to the analyses from 2016.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| Total suspended solids | TSS | mg/L | 28 | 6 | 79% |
| Total phosphorus | TP | mg/L | 0.08 | 0.03 | |
| Total nitrogen | TN | mg/L | 0.78 | 0.45 | 42% |
| Total copper | Cu | mg/L | 0.015 | 0.008 | 47% |
| Total zinc | Zn | mg/L | 0.06 | 0.027 | 55% |
Inlet: stormwater at the inlet of the media filters. Outlet: outlet of the media filters. Averages of flow-weighted composite samples from 15 storm events, 2014 to 2017 (copper and zinc from 9 events). Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.