COD removal from traffic area oil separator effluent by settling and electrocoagulation
Oily water collected from oil and grease separators serving traffic areas in Croatia was treated in a batch pilot unit made of a main reactor and a separator. The water was dark, odorous and high in organic load and mineral oil. Two pretreatments were compared ahead of an electro-Fenton and electrocoagulation sequence; in the line listed here the raw water was simply settled.
Treatment line
- 01Primary sedimentationGravity settling for 24 hours, then 80 litres decanted to the reactor.
- 02Stainless steel electrodesOxidation of organic matter for 20 minutes, then settling and decanting.
- 03Iron electrodes15 minutes of treatment, then precipitation and decanting.
- 04Aluminium electrodesCoagulation for 20 minutes, then settling and decanting.
What the source found
Settling removed little COD but over half the mineral oil, and the full sequence removed 89% of COD. Aluminium and nickel rose in the treated water because of the electrode materials. Mixing previously generated electrochemical sludge into the raw water before settling gave higher final removal than plain settling.
Batch runs at room temperature with the raw water analysed before treatment, after settling and after the electrode steps.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| Mineral oil | mg/L | 3.96 | 1.1 | ||
| COD | COD | mg/L | 1,583 | 170 | 89% |
| Aluminium | Al | mg/L | 0.01 | 0.86 | |
| Arsenic | As | mg/L | 0.000173 | 0.000025 | 86% |
| Calcium | Ca | mg/L | 7.89 | 1.28 | 84% |
| Cadmium | Cd | mg/L | 0.000003 | 0 | 92% |
| Chromium | Cr | mg/L | 0.002272 | 0.00035 | 85% |
| Copper | Cu | mg/L | 0.000675 | below the detection limit (printed as 0) | >99.9% |
| Iron | Fe | mg/L | 0.21 | 0.06 | 71% |
| Potassium | K | mg/L | 0.86 | 0.66 | 23% |
| Magnesium | Mg | mg/L | 0.52 | 0.16 | 69% |
| Manganese | Mn | mg/L | 0.032606 | 0.000911 | 97% |
| Sodium | Na | mg/L | 2.92 | 2.49 | 15% |
| Nickel | Ni | mg/L | 0.000109 | 0.002618 | |
| Lead | Pb | mg/L | 0.000113 | 0.000008 | 93% |
| Silicon | Si | mg/L | 0.81 | below the detection limit (printed as 0) | >99.9% |
| Tin | Sn | mg/L | 0.000027 | 0 | 99.3% |
| Zinc | Zn | mg/L | 0.002704 | 0.000458 | 83% |
Inlet: raw oily water from traffic area oil separators. Outlet: treated water after the electrode steps. One batch run with plain settling ahead of the electrode steps; single analyses of raw and treated water. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.