COD and BOD removal from dairy wastewater by anaerobic pretreatment and activated sludge
A dairy in Hamadan Province, western Iran, has a nominal capacity of about 55 tonnes a day of pasteurised milk, cheese and yoghurt and can process about 70 m³ of milk a day. It produces about 140 m³/day of wastewater, which is treated in a plant on site. The plant also has solids drying beds.
Treatment line
- 01Screening
- 02Equalisation tank
- 03Clarification tank
- 04Anaerobic systemUsed as pretreatment ahead of the aerobic stage.
- 05Activated sludgeAerated biological stage.
- 06Disinfection
What the source found
The plant removed about 89% of BOD, 89% of COD and 72% of suspended solids. The treated water still exceeded the national limits for suspended solids and phosphate, and for BOD and COD for recharge or discharge to surface water, so it was not fit for discharge to surface water or the ground. Better settling, a stronger biological stage and improved equipment upkeep and operator training were recommended.
Grab samples of raw and treated wastewater taken at peak hours on five random days in each of the wet and dry seasons of 2014 to 2015.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| COD | COD | mg/l | 1,982.8 | 222.16 | 89% |
| BOD5 | BOD5 | mg/l | 1,041 | 112.2 | 89% |
| Total suspended solids | TSS | mg/l | 852 | 241 | 72% |
| Nitrate | NO3− | mg/l | 5.98 | 6.75 | |
| Phosphate | PO43− | mg/l | 69.5 | 34 | 51% |
| pH | 6.171 | 7.42 | |||
| Temperature | °C | 30.75 | 29.45 |
Inlet: raw wastewater entering the plant. Outlet: treated wastewater leaving the plant. Means of 10 grab samples over a wet and a dry season in 2014 and 2015. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.