    Ammonium and salt removal from dairy digestate by nanofiltration for reuse and recovery

    A dairy in Thessaly, Greece, sends its process effluents (cheese whey, lactose, flushings and cleaning water) to an industrial anaerobic digestion plant, whose liquid digestate is filtered by ultrafiltration membranes. The filtered digestate was acidified with sulfuric acid to lower its alkalinity and then concentrated in a nanofiltration pilot unit on the dairy site, so that the permeate could be reused or used for restricted irrigation and the concentrate used for struvite recovery.

    Treatment line

    1. 01Nanofiltration pilot unitTwo spiral-wound modules in one pressure vessel, 5.2 m² of membrane, run in batch mode at 9 to 10 bar with the concentrate recycled to the feed tank until about half the feed was collected as permeate.

    What the source found

    The membranes held back most of the dissolved salts, and the permeate met the requirements for restricted irrigation or reuse. In the last pilot run the permeate held 95% less ammonium and 97% less sulfate and chloride than the feed. When more than about half of the feed was recovered as permeate the flux fell sharply, probably because of scaling, and cleaning did not fully restore the membrane permeability.

    Batch pilot runs on 250 to 1000 L lots of acidified filtered digestate, with the feed, final concentrate and collected permeate analysed for each run.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH7.35.8
    Electrical conductivityECμS/cm9,670465
    MagnesiumMgmg/L34197%
    Ammonium nitrogenNH4-Nmg/L26214.195%
    Phosphate as phosphorusPO4-Pmg/L11815.487%
    ChlorideCl−mg/L99733.297%
    SulfateSO42−mg/L59919.797%
    SodiumNamg/L1,94278.996%
    PotassiumKmg/L25813.295%
    CalciumCamg/LND<2
    AlkalinityAlkmg CaCO3/L3,283181.2
    Total organic carbonTOCmg/L5.8

    Inlet: acidified filtered digestate fed to nanofiltration. Outlet: cumulative nanofiltration permeate. One batch pilot run with about 56% permeate recovery; feed and collected permeate analysed once. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.