COD and suspended solids removal from beverage wastewater by flotation and membrane bioreactor
A pilot treatment plant with a design capacity of 1 m³ a day treats wastewater from a beverage manufacturing factory in Nilai, Negeri Sembilan. The treated water must meet national industrial discharge standards before it goes to the drain. The pilot compared two membrane types, hollow fibre and flat sheet, added to the biological stage of a conventional line.
Treatment line
- 01Equalisation tankMixed by a submersible mixer.
- 02Chemical reaction tankCoagulation and flocculation take place here.
- 03Dissolved air flotationSeparates solids from the water; the floated sludge goes to a holding tank.
- 04Activated sludge reactor with submerged membranesHollow-fibre modules sit in the activated sludge reactor; flat-sheet modules sit in a separate membrane tank fed with part of the flotation effluent, both aerated from below.
What the source found
From the equalisation tank to the hollow-fibre membrane outlet, COD fell by 99% and suspended solids by 97%. Effluent from the hollow-fibre line met the stricter discharge standard, while the flat-sheet line, which received stronger wastewater, met only the less strict one. The flat-sheet membrane fouled less and ran without chemical cleaning, while the hollow-fibre membrane needed repeated chemical cleaning.
Samples taken at the equalisation tank inlet, the flotation outlet and the membrane outlet over three consecutive weeks, with each membrane type run at two biomass levels; the figures shown are from the hollow-fibre membrane at the lower biomass level.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 7.4 | ||||
| COD | COD | mg/L | 1,710 | 16.9 | 99.0% |
| Total suspended solids | TSS | mg/L | 140 | 3.8 | 97% |
Inlet: raw wastewater at the equalisation tank inlet. Outlet: hollow-fibre membrane permeate. Averages over three weeks for the hollow-fibre membrane line at the lower biomass level. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.