BOD and COD removal from winery wastewater by coagulation, encapsulated bacteria and SBR
An outdoor pilot unit in Melbourne treated winery wastewater taken from a winery's settling pond after three to four months of storage, aiming at a simple process for small and medium wineries. The stored wastewater was acidic at times and poor in nitrogen and phosphorus, so its acidity was corrected and nutrients were added. The aim was effluent of a quality fit for irrigation.
Treatment line
- 01Feed filterFine filter on the feed ahead of the equalisation tank to cut suspended solids.
- 02Equalisation tank12 hours; sodium hydroxide added to correct acidity, polyaluminium chloride added as coagulant and nutrients dosed, with stirring.
- 03Sedimentation tank12 hours; settled solids drawn off from the bottom.
- 04Encapsulated-biomass bioreactor2 days, aerated and heated, holding 500 membrane capsules with a selected phenol-degrading bacterium to break down hard-to-degrade compounds.
- 05Sequencing batch reactor2 days of activated sludge in cycles of 47 hours aeration, half an hour settling and half an hour discharge.
What the source found
Treatment only became stable once both bioreactors were heated, after about 20 days. BOD fell by 97% and COD removal rose over time to about 90% in the last month, and the effluent met the requirements for discharge to a municipal treatment plant. Sludge escaping from the batch reactor sometimes raised effluent solids until regular sludge wasting started, and sodium, thought to come from the winery's cleaning agent, rose in the effluent to a level that is a risk to soil.
Samples at the system inlet and outlet twice a week for COD and once a week for BOD over 100 days of winter operation.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 6.3 | ||||
| COD | COD | mg/L | 3,920 | 889 | |
| BOD | BOD | mg/L | 2,550 | 87.5 | 97% |
| Total phosphorus | TP | mg/L | 9.8 | ||
| Total Kjeldahl nitrogen | TKN | mg/L | 11.5 | ||
| Total suspended solids | TSS | mg/L | 102 |
Inlet: stored winery wastewater fed to the pilot. Outlet: effluent of the sequencing batch reactor. Averages over 100 days of winter operation, COD twice and BOD once a week. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.