Water Treatment Equipment
Find the right water treatment equipment partner for your project. Browse the providers listed below, or post your project and our engineers shortlist the providers that fit.
20 specialist providers · 393 related · 41 countries
Showing 1 to 20 of 413
Buyer's guide
The buyer's guide to water treatment
Water Treatment Equipment: Package Plants, Vessels, Chemical Dosing, and Process Skids
Water treatment equipment encompasses all physical plant and apparatus used to treat water and wastewater: civil structures (tanks, chambers, channels), mechanical equipment (screens, pumps, aerators, mixers, centrifuges, presses), process vessels (filters, membrane housings, ion exchange columns, adsorbers), and chemical dosing systems (storage tanks, metering pumps, mixing systems). Equipment procurement in the water industry follows the Water Industry Act 1991 supply chain requirements, Ofwat procurement guidelines, NEC4 contract framework, and EU/UK procurement regulations (Public Contracts Regulations 2015 for above-threshold contracts).
Manufacturer quality systems: ISO 9001:2015 for design and manufacture; CE/UKCA marking for pressure equipment (PED/UKPEDD), machinery (Machinery Directive), and electrical equipment; ATEX certification for equipment in classified hazardous areas (wet wells, gas holder rooms). Key equipment categories: screens and screening equipment (drum screens, band screens, fine screens to 0.1 mm); clarification equipment (lamella settlers, DAF systems, tube settlers); filtration vessels (pressure filter vessels, open concrete RGF, membrane racks); chemical dosing (day tanks, metering pumps, bund, mixer, diffuser); ultraviolet disinfection systems (validated per DVGW W 294 or US EPA UVDGM); control panels and SCADA.
Package water treatment plants are pre-engineered, factory-assembled, and tested units that integrate multiple treatment processes in a compact footprint, reducing site installation time and civil engineering cost. Applications: small water utilities (50 to 5,000 m3/day), remote communities, emergency water supply, military forward operating bases, humanitarian response (UNHCR, ICRC). Package plant configurations: conventional coagulation + clarification + pressure filtration + UV + chlorination from the established package-plant manufacturers; membrane (UF or MF) package plants from the major membrane suppliers; RO package plants for brackish or seawater from the major desalination suppliers. Container-mounted or skid-mounted designs: ISO 20-ft or 40-ft shipping containers provide weatherproof housing, enabling airfreight or road transport to remote locations. Modular capacity expansion: containerised modules can be added in parallel (N+1 configuration) to increase capacity without new civil structures. Procurement: package plants are procured as designed-build (D&B) under JCT or NEC4 contracts; performance guaranteed by supplier; factory acceptance test (FAT) before dispatch; site acceptance test (SAT) after commissioning.
Chemical dosing equipment selection and design: accurate, reliable chemical dosing is critical for treatment process performance and regulatory compliance. Metering pump technologies: peristaltic pumps: no seals, handles viscous or abrasive chemicals (lime slurry, polymer), maximum flow 0.001 to 100 m3/h per pump; diaphragm dosing pumps: compact, precise, 1 to 4,000 L/h range, can dose against 10 to 16 bar back pressure; progressive cavity (screw) pumps: high viscosity slurries (lime, polymer make-up), 0.1 to 100 m3/h. Chemical day tanks: HDPE (PE100), polypropylene, or fibreglass (GRP) with full bunding per PPG 2 (110 percent secondary containment); COSHH assessment for each chemical; tank sizing typically 1 to 2 weeks' supply. Lime slurry systems: specialist equipment (lime slakers, ball mill slakers, paste slakers) for preparing Ca(OH)2 slurry from quicklime (CaO) or hydrated lime powder; ATEX classification for lime dust; supplied by specialist lime equipment and reagent suppliers. Polymer make-up and dosing: automated polymer preparation unit (dissolve emulsion or powder polymer to 0.2 to 0.5 percent solution with controlled maturation time 20 to 45 minutes); supplied as proprietary polymer make-up units.
Frequently asked questions
What equipment is in a water treatment plant?
A conventional surface water treatment plant includes these main equipment categories: (1) Intake and screening: wedgewire screens (1 to 3 mm aperture), drum or band screens (0.5 to 1 mm), intake pumps; (2) Coagulation: rapid mixing (inline static mixer or mechanical flash mixer), coagulant dosing pump and day tank; (3) Flocculation: slow mixers (turbine or paddle type, G 20 to 80 s-1) in 2 to 3 stage chambers; (4) Clarification: circular or rectangular sedimentation tanks with scraper mechanism; dissolved air flotation (DAF) system (pressure vessel, recycle pump, flotation tank, sludge collector); lamella settlers (inclined plate packs); (5) Filtration: rapid gravity filters (RGF) - concrete filter beds, underdrain nozzles, anthracite/sand media, backwash pumps and air compressors - or pressure filters or membrane racks; (6) Disinfection: UV reactors (low-pressure lamp, 40 mJ/cm2 validated); chlorination (gas chlorinators or sodium hypochlorite dosing); (7) pH and chemistry control: lime or soda ash dosing for pH; fluorosilicic acid dosing for fluoridation; orthophosphate dosing for corrosion control; (8) Sludge handling: sludge thickener, centrifuge or belt press for sludge dewatering; (9) SCADA and instrumentation: flow meters, turbidity monitors, pH/DO probes, chlorine analysers, level indicators, pressure transmitters.
How long does water treatment equipment last?
Asset life expectancy for water treatment equipment (UK water industry asset management benchmarks, Ofwat/WRc CAPEX data): Civil structures (concrete tanks, filter beds, pump chambers): 50 to 80 years; structural failure triggers rehabilitation (crack injection, lining, shotcrete) rather than replacement. Process plant buildings: 40 to 60 years. Large rotating plant (pumps, compressors): 15 to 25 years with bearing replacements at 5 to 10 years; impeller/casing replacement at 10 to 15 years. Centrifuges (dewatering): 15 to 20 years main frame; bowl and scroll wear parts 5 to 8 years. Membranes (RO, NF, UF, MF): 5 to 10 years for spiral-wound RO/NF; 5 to 10 years for hollow fibre UF/MF. UV lamps: 8,000 to 16,000 hours (1 to 2 years continuous operation). Control panels/SCADA: 15 to 20 years for hardware; software and cybersecurity requires upgrade every 5 to 10 years. Ion exchange resin: 10 to 20 years with good feed water quality; shorter if iron/chlorine fouled. Chemical dosing pumps: 5 to 10 years for diaphragm pumps; 2 to 5 years for peristaltic tubes. Gate/butterfly valves: 25 to 40 years main body; gland and seat replacement at 10 to 20 years. Instrumentation (flow meters, analysers): 10 to 15 years; sensors/probes 1 to 3 years.
What are package water treatment plants?
Package water treatment plants (also called compact or modular water treatment systems) are pre-engineered, factory-built units integrating multiple treatment processes in a single skid or containerised module. Key characteristics: (1) Turnkey supply: manufacturer designs, fabricates, tests (FAT), delivers, and commissions the complete unit; client provides civil works (foundation, utilities connections); (2) Compact footprint: processes typically arranged vertically or in series within an ISO container (6 to 12 m length) or skid (2 to 6 m wide); (3) Factory testing: complete process operation tested at manufacturer's works before delivery - reduces site commissioning time and risk; (4) Rated capacity: typically 50 to 5,000 m3/day for drinking water; 10 to 2,000 m3/day for wastewater; (5) Standard configurations: coagulation + clarification + filtration + UV + chlorination (conventional surface water); UF + chlorination (groundwater); RO + post-treatment (brackish or seawater desalination); (6) Approved for potable supply: DWI/WRAS-approved materials throughout, validated processes (UV to DVGW W 294). Applications: rural water supply (remote villages, developing countries), emergency response (military, disaster relief, UNHCR), industrial sites, golf courses and irrigation, temporary water supply during works on permanent infrastructure. Major suppliers: the established package-plant manufacturers and mobile water service providers.
What chemicals are dosed in water treatment plants?
Chemical dosing in drinking water treatment works (England/Wales DWI-approved chemicals only): (1) Coagulants: aluminium sulphate (alum, 5 to 50 mg/L), polyaluminium chloride (PACl, 1 to 20 mg/L as Al), ferric sulphate (5 to 50 mg/L), ferric chloride - primary treatment step removing turbidity, colour, and NOM; (2) Flocculant aids: anionic or cationic polyacrylamide (PAM, 0.1 to 0.5 mg/L) - improves floc settleability; (3) pH adjustment: sulphuric acid (96 percent, 5 to 30 mg/L for pH reduction); lime Ca(OH)2 slurry or soda ash Na2CO3 (5 to 50 mg/L for pH increase and softening); (4) Disinfectants: sodium hypochlorite (NaOCl, 5 to 14 percent, dose 0.5 to 5 mg/L Cl2); chlorine gas (Cl2, specialist sites, high volume); chlorine dioxide (ClO2, 0.1 to 0.8 mg/L, on-site generated); monochloramine (NH2Cl, post-chlorination with ammonia dose); (5) Corrosion inhibitors: orthophosphate (sodium orthophosphate or polyphosphate, 0.5 to 1.0 mg/L as P - Langelier control, lead reduction); (6) Fluoride: fluorosilicic acid (H2SiF6, 25 percent, dose 0.05 to 0.2 mg/L as F to achieve 0.7 mg/L target in fluoridated zones); (7) Activated carbon (PAC, 5 to 30 mg/L): seasonal taste, odour, algal toxin control; (8) Carbon dioxide (CO2): post-lime softening recarbonation to reduce pH to 8.0 to 8.5. All chemicals: DWI Regulation 31 approval mandatory; BS EN/ISO specifications; current SDS required on site; COSHH assessment per chemical.
Illustrative scenario · Rural drinking water supply, Wales
A composite drawn from typical projects in this category, not a single client engagement. Figures are indicative.
- Challenge
- A rural Welsh water supply zone serving 2,400 properties relied on a 1970s gravity-fed package plant treating upland reservoir water. The plant had failed 22 DWI turbidity compliance tests in the preceding three years, triggered by autumn catchment flushing events pushing turbidity above 4 NTU at consumer taps. The site had no chemical coagulation capability, relying only on slow sand filtration and chlorination.
- Approach
- A containerised package plant (500 m3/day) was specified and factory acceptance tested before despatch. The unit integrated PACl coagulation, dissolved air flotation, dual-media pressure filtration, UV disinfection (40 mJ/cm2, DVGW W 294 validated), and sodium hypochlorite dosing within a single 12 m ISO container. All wetted materials WRAS-approved. Chemical day tanks (PACl 1,000 L, NaOCl 500 L) installed on bunded pads with COSHH-compliant secondary containment.
- Outcome
- Commissioned in 14 weeks from contract award. Filtered water turbidity consistently below 0.08 NTU during the subsequent two autumn events (previously greater than 4 NTU). Zero DWI compliance failures in the following 18-month period. The containerised format allowed planning consent under permitted development rights, saving 6 months compared to a traditional bespoke build.
Questions to ask shortlisted providers
5
- 01
What is the design flow rate range and peak-to-average flow ratio the equipment can handle, and does it include a bypass for maintenance?
Water demand varies diurnally and seasonally; equipment that only operates at design flow (no turndown capability below 50 percent) will cycle inefficiently and wear dosing pumps prematurely.
- 02
Have the chemical dosing systems and all wetted materials been approved to DWI Regulation 31 and WRAS, and can you provide the approval certificates?
Any chemical or material in contact with drinking water must hold current DWI/WRAS approval; retrofitting non-approved materials causes regulatory compliance failures and supply suspension orders.
- 03
What is the expected electrical consumption per m3 treated, and has this been measured at a reference installation at similar flow and quality conditions?
Energy is typically the largest operating cost for membrane or UV-intensive treatment; published energy figures that do not reflect real-world site conditions are not a reliable basis for operating cost projections.
- 04
What is the minimum practical maintenance interval, and can the equipment continue operating at reduced capacity while maintenance is carried out?
Rural sites often have limited access and infrequent operator visits; knowing whether maintenance requires plant shutdown informs the need for buffer storage and backup supply arrangements.
- 05
What instrumentation is included as standard for SCADA integration, and does the control system support remote alarming and data logging?
UK water supply regulations increasingly expect real-time monitoring and alarm data to be recorded and accessible for DWI inspection; SCADA-ready equipment avoids expensive retrofitting.
What drives cost in this category
4
- Technology complexity and number of treatment stages
- A simple UV disinfection skid costs GBP 15,000 to 50,000; a full package coagulation-filtration-UV plant costs GBP 150,000 to 600,000 for 500 m3/day capacity; each added treatment stage increases CAPEX by 20 to 40 percent.
- Stainless steel vs carbon steel construction
- All-316L stainless steel construction adds 25 to 50 percent to fabrication cost versus carbon steel but eliminates corrosion maintenance over the 25-year equipment life; justified for coastal or high-chloride water environments.
- Containerised versus skid-mounted design
- Containerisation adds GBP 15,000 to 30,000 versus open-skid designs but provides weatherproof housing, reduces civil engineering cost (no building required), and allows airfreight or road transport to remote sites.
- Instrumentation and SCADA specification
- Basic local HMI with manual logging adds GBP 5,000 to 10,000; full SCADA with online turbidity, chlorine, and flow monitoring plus 4G data telemetry adds GBP 20,000 to 60,000; regulatory expectations increasingly require online data capture.
Key regulations and standards
4
- Water Supply (Water Quality) Regulations 2016
- England regulations (SI 2016/614): all equipment used in potable water treatment must meet DWI Regulation 31 approval requirements; chemical dosing, filtration media, and UV systems must be individually approved; DWI maintains the approved products list and processes approval applications.
- PSSR 2000 and PED
- Pressure Systems Safety Regulations 2000 (SI 2000/128) and Pressure Equipment (Safety) Regulations 2016: pressure vessels in treatment equipment (filter vessels, membrane housings) operating above 0.5 bar must be CE/UKCA marked under PED; written scheme of examination required; periodic inspection by competent person (typically every 2 to 5 years).
- WRAS Approval
- Water Regulations Advisory Scheme: all fittings, valves, meters, and components in contact with potable water must be WRAS-approved; WRAS approval list at wras.co.uk; installation must follow approved product data sheets; deviations require re-assessment.
- Permitted Development Rights (PDR)
- Town and Country Planning (General Permitted Development) (England) Order 2015 (SI 2015/596), Schedule 2 Part 18: water treatment infrastructure installations may qualify as permitted development if volume and footprint thresholds are met; containerised units often avoid formal planning consent, reducing programme by 4 to 9 months.
Aguato Marketplace
Have a water challenge to solve?
Post your project and our engineers shortlist the providers that fit. Compare proposals, credentials and pricing in one place.