Water tools

    High-rate trickling filter sizing

    Trickling filters are sized on organic loading and checked on hydraulic loading. The NRC relation then predicts the removal, which you compare with the effluent target.

    Keep below about 100 to 150 mg/L for stone media (oxygen limitation).
    High rate after an anaerobic reactor: 0.5 to 1.0.
    Stone 2 to 3 m; plastic media up to 6 m.
    0 to 2.
    0.8 to 1.0 high rate without nitrification.
    Filter
    Media volume
    371m³
    Total area
    185m²
    Diameter per unit
    10.9m
    Hydraulic loading, average
    16.2m³/m²·d
    Hydraulic loading, max day
    19.4m³/m²·d
    Hydraulic loading, max hour
    29.1m³/m²·d
    Performance
    BOD₅ removal (NRC)
    71%
    Effluent BOD₅
    30mg/L
    Sludge
    Sludge produced
    168kg TSS/d
    Volatile sludge
    126kg VSS/d
    Sludge volume
    16.4m³/d

    How it works

    Media volume from the organic loading, area from the depth, then hydraulic loading as a check:

    V=QSoLvA=VHLh=QA(1)

    Removal by the NRC relation with the recirculation factor:

    E=1001+0.443Lv/FF=1+R(1+R/10)2(2)
    Se=So(1−E/100)Psludge=YQ(So−Se)Vsludge=PsludgeγCsludge(3)
    where
    V
    media volume, m³
    Q
    flow, m³/d
    So
    influent BOD₅, kg/m³
    Lv
    volumetric organic loading, kg BOD₅/m³·d
    A
    filter area, m²
    H
    packing depth, m
    Lh
    hydraulic loading, m³/m²·d
    E
    BOD₅ removal, %
    F
    recirculation factor
    R
    recycle ratio
    Se
    effluent BOD₅, mg/L
    Psludge
    sludge produced, kg TSS/d
    Y
    sludge yield, kg TSS per kg BOD₅ removed
    Vsludge
    sludge volume, m³/d
    γ
    sludge density, about 1,020 kg/m³
    Csludge
    settled sludge solids, fraction

    The NRC relation was developed for stone beds fed settled wastewater; for anaerobic effluents it should be used with caution. Stone media clog at high organic loads; plastic media allow deeper beds and higher loadings. Add a secondary settler at 16 to 32 m³/m²·d average surface loading.

    Related reading

    These calculators use standard published formulas and are provided for preliminary engineering guidance. Confirm against measured data and vendor projections before design. Model your full water matrix in Nepti or post your project to compare provider proposals.