Water tools
Gravity thickener area from batch settling data
A thickener fails when the solids flux it must pass exceeds what the blanket can carry. Batch settling tests at several concentrations give the gravity flux curve; the underflow you want sets the limit.
How it works
Each batch test gives the gravity flux at its concentration, and the underflow adds a bulk flux:
The limiting flux is the intercept of the line from the underflow concentration tangent to the gravity flux curve, which in algebra is the minimum over the descending limb:
- gravity solids flux, kg/m²·h
- interface settling velocity at concentration C, m/h
- solids concentration, kg/m³
- total flux, kg/m²·h
- underflow velocity, m/h
- limiting flux, kg/m²·h
- underflow concentration, kg/m³
- underflow flow, m³/h
- feed flow, m³/h
- feed solids, kg/m³
- thickener area, m²
Effluent solids are neglected against the feed and underflow. If the applied loading exceeds the limiting flux the blanket rises and solids overflow. The velocities are interpolated between test points; the printed construction in practice is graphical, so expect a few percent of reading tolerance.
Related reading
These calculators use standard published formulas and are provided for preliminary engineering guidance. Confirm against measured data and vendor projections before design. Model your full water matrix in Nepti or post your project to compare provider proposals.