    Normalise RO operating data to standard conditions

    Raw permeate flow can stay constant while the membrane fouls, because operators raise pressure to hold it. Normalising to one reference condition strips out temperature, pressure and feed quality and leaves the membrane's own trend.

    Any unit; the standardised flow has the same unit.
    Reference (manufacturer or start-up) condition.
    Standardised permeate flow
    10,801m³/d

    Compare this figure between dates: a fall of 10 to 15% from the clean baseline is the usual cleaning trigger.

    Standardised salt passage
    5.72%
    Measured salt passage
    4.60%
    Temperature correction factor
    1.513
    Net driving pressure, measured
    26.54bar
    Average feed-concentrate TDS
    7,828mg/L
    Osmotic pressure in the channel
    6.33bar

    How it works

    Net driving pressure from the measured pressures and the osmotic pressures of the average feed-concentrate and the permeate:

    NDP=PF+PC2−PP−(πFC−πP)CFC=CFrln11−r(1)

    Standardised permeate flow and salt passage, with the temperature correction factor unless the manufacturer supplies one:

    QP,S=QP,MTCFNDPSNDPMTCF=1.03TS−TM(2)
    SPS=SPMNDPMNDPSCFC,SCFC,MCF,MCF,S(3)
    where
    NDP
    net driving pressure, bar
    PF,PC,PP
    feed, concentrate and permeate pressure, bar
    πFC,πP
    osmotic pressure of the average feed-concentrate and the permeate, bar
    CFC
    average feed-concentrate concentration, mg/L
    CF
    feed concentration, mg/L
    r
    recovery, fraction
    QP
    permeate flow
    TCF
    temperature correction factor
    TS,TM
    standard and measured temperature, °C
    SP
    salt passage, permeate over feed concentration
    S,M
    standard and measured condition

    Standardise each stage separately in multi-stage systems. The 1.03 per degree factor is a viscosity approximation; the standard condition must fix feed flow and feed concentration as well as pressure. Different manuals normalise in slightly different ways; use one consistently.

    Related reading

    These calculators use standard published formulas and are provided for preliminary engineering guidance. Confirm against measured data and vendor projections before design. Model your full water matrix in Nepti or post your project to compare provider proposals.