Normalise RO operating data to standard conditions
Raw permeate flow can stay constant while the membrane fouls, because operators raise pressure to hold it. Normalising to one reference condition strips out temperature, pressure and feed quality and leaves the membrane's own trend.
Compare this figure between dates: a fall of 10 to 15% from the clean baseline is the usual cleaning trigger.
How it works
Net driving pressure from the measured pressures and the osmotic pressures of the average feed-concentrate and the permeate:
Standardised permeate flow and salt passage, with the temperature correction factor unless the manufacturer supplies one:
- net driving pressure, bar
- feed, concentrate and permeate pressure, bar
- osmotic pressure of the average feed-concentrate and the permeate, bar
- average feed-concentrate concentration, mg/L
- feed concentration, mg/L
- recovery, fraction
- permeate flow
- temperature correction factor
- standard and measured temperature, °C
- salt passage, permeate over feed concentration
- standard and measured condition
Standardise each stage separately in multi-stage systems. The 1.03 per degree factor is a viscosity approximation; the standard condition must fix feed flow and feed concentration as well as pressure. Different manuals normalise in slightly different ways; use one consistently.