Rejection reads as a percentage; log removal reads as a count of nines. For pathogens and challenge tests the log form is the one regulators use.
An LRV of 4 is 99.99% rejection; of 6, 99.9999%.
How it works
- rejection, fraction
- feed and permeate concentration, any common unit
- log removal value
When the permeate is below detection, the LRV is a lower bound computed with the detection limit. Rejection is not a step function at the pore rating: pore-size distribution, particle shape and charge all matter. Microfiltration should not be relied on for complete virus removal; ultrafiltration virus removal depends on the molecular weight cut-off. Adsorption and cake filtration add removal that is not credited.