Water tools

    Aeration energy and cost by tariff window

    Aeration is usually the largest electricity line of a treatment plant. Map the three load levels onto the day's tariff windows and see where the money goes.

    From the diffused aeration calculator.
    Daily cost
    563per day
    Yearly cost
    205,462per year
    Energy per day
    6,421kWh/d
    Peak window share of cost
    46%
    Blower shaft power
    Power at low load
    206kW
    Power at average load
    268kW
    Power at peak load
    360kW

    How it works

    Shaft power at each load from adiabatic compression, with the air mass flow from the oxygen flow and the discharge pressure held constant across loads (which slightly overstates night-time power):

    Wair=WO20.23P=WairRTin29.7ne[(pabs/pin)n−1](1)

    Cost per window is hours × power × tariff; the day sums the windows and the year multiplies by 365:

    Cday=∑khkPkckEday=∑khkPk(2)
    where
    Wair
    air mass flow, kg/s
    WO2
    oxygen through the blowers, kg O₂/h
    P
    blower shaft power, kW
    R
    gas constant, 8.314 J/mol·K
    Tin
    inlet air temperature, K
    n
    polytropic exponent, 0.283
    e
    blower efficiency
    pabs,pin
    absolute discharge and inlet pressure, kPa
    hk
    hours in tariff window k
    Pk
    power during window k, kW
    ck
    tariff in window k, per kWh

    Motor and drive losses are not included: divide by the wire-to-shaft efficiency for metered energy. Currency follows the tariff you enter.